Currently a list is used to save all meter profile ids, which is
not efficient when looking up profile from huge mount of profiles.

This changes to use a l3 table instead to save meter profile ids,
so as to improve the lookup performance.

Signed-off-by: Shun Hao <shunh@nvidia.com>
Acked-by: Matan Azrad <matan@nvidia.com>
---
 drivers/net/mlx5/linux/mlx5_os.c   |  6 +++-
 drivers/net/mlx5/mlx5.h            |  2 +-
 drivers/net/mlx5/mlx5_flow_meter.c | 53 ++++++++++++++++++++----------
 drivers/net/mlx5/windows/mlx5_os.c |  6 +++-
 4 files changed, 47 insertions(+), 20 deletions(-)

diff --git a/drivers/net/mlx5/linux/mlx5_os.c b/drivers/net/mlx5/linux/mlx5_os.c
index 92b3009786..b3f9e392ab 100644
--- a/drivers/net/mlx5/linux/mlx5_os.c
+++ b/drivers/net/mlx5/linux/mlx5_os.c
@@ -1570,7 +1570,9 @@ mlx5_dev_spawn(struct rte_device *dpdk_dev,
 	priv->ctrl_flows = 0;
 	rte_spinlock_init(&priv->flow_list_lock);
 	TAILQ_INIT(&priv->flow_meters);
-	TAILQ_INIT(&priv->flow_meter_profiles);
+	priv->mtr_profile_tbl = mlx5_l3t_create(MLX5_L3T_TYPE_PTR);
+	if (!priv->mtr_profile_tbl)
+		goto error;
 	/* Hint libmlx5 to use PMD allocator for data plane resources */
 	mlx5_glue->dv_set_context_attr(sh->ctx,
 			MLX5DV_CTX_ATTR_BUF_ALLOCATORS,
@@ -1713,6 +1715,8 @@ mlx5_dev_spawn(struct rte_device *dpdk_dev,
 			mlx5_vlan_vmwa_exit(priv->vmwa_context);
 		if (eth_dev && priv->drop_queue.hrxq)
 			mlx5_drop_action_destroy(eth_dev);
+		if (priv->mtr_profile_tbl)
+			mlx5_l3t_destroy(priv->mtr_profile_tbl);
 		if (own_domain_id)
 			claim_zero(rte_eth_switch_domain_free(priv->domain_id));
 		mlx5_cache_list_destroy(&priv->hrxqs);
diff --git a/drivers/net/mlx5/mlx5.h b/drivers/net/mlx5/mlx5.h
index 1b2dc8f815..0226327bc3 100644
--- a/drivers/net/mlx5/mlx5.h
+++ b/drivers/net/mlx5/mlx5.h
@@ -1373,8 +1373,8 @@ struct mlx5_priv {
 	/* Hash table of Rx metadata register copy table. */
 	uint8_t mtr_sfx_reg; /* Meter prefix-suffix flow match REG_C. */
 	uint8_t mtr_color_reg; /* Meter color match REG_C. */
-	struct mlx5_mtr_profiles flow_meter_profiles; /* MTR profile list. */
 	struct mlx5_legacy_flow_meters flow_meters; /* MTR list. */
+	struct mlx5_l3t_tbl *mtr_profile_tbl; /* Meter index lookup table. */
 	struct mlx5_l3t_tbl *mtr_idx_tbl; /* Meter index lookup table. */
 	uint8_t skip_default_rss_reta; /* Skip configuration of default reta. */
 	uint8_t fdb_def_rule; /* Whether fdb jump to table 1 is configured. */
diff --git a/drivers/net/mlx5/mlx5_flow_meter.c b/drivers/net/mlx5/mlx5_flow_meter.c
index d7ce5cd2f6..87c5782956 100644
--- a/drivers/net/mlx5/mlx5_flow_meter.c
+++ b/drivers/net/mlx5/mlx5_flow_meter.c
@@ -91,13 +91,20 @@ mlx5_flow_meter_action_create(struct mlx5_priv *priv,
 static struct mlx5_flow_meter_profile *
 mlx5_flow_meter_profile_find(struct mlx5_priv *priv, uint32_t meter_profile_id)
 {
-	struct mlx5_mtr_profiles *fmps = &priv->flow_meter_profiles;
 	struct mlx5_flow_meter_profile *fmp;
+	union mlx5_l3t_data data;
+	int32_t ret;
 
-	TAILQ_FOREACH(fmp, fmps, next)
-		if (meter_profile_id == fmp->id)
-			return fmp;
-	return NULL;
+	if (mlx5_l3t_get_entry(priv->mtr_profile_tbl,
+			       meter_profile_id, &data) || !data.ptr)
+		return NULL;
+	fmp = data.ptr;
+	/* Remove reference taken by the mlx5_l3t_get_entry. */
+	ret = mlx5_l3t_clear_entry(priv->mtr_profile_tbl,
+				   meter_profile_id);
+	if (!ret || ret == -1)
+		return NULL;
+	return fmp;
 }
 
 /**
@@ -399,8 +406,8 @@ mlx5_flow_meter_profile_add(struct rte_eth_dev *dev,
 		       struct rte_mtr_error *error)
 {
 	struct mlx5_priv *priv = dev->data->dev_private;
-	struct mlx5_mtr_profiles *fmps = &priv->flow_meter_profiles;
 	struct mlx5_flow_meter_profile *fmp;
+	union mlx5_l3t_data data;
 	int ret;
 
 	if (!priv->mtr_en)
@@ -427,8 +434,13 @@ mlx5_flow_meter_profile_add(struct rte_eth_dev *dev,
 	ret = mlx5_flow_meter_param_fill(fmp, priv, error);
 	if (ret)
 		goto error;
-	/* Add to list. */
-	TAILQ_INSERT_TAIL(fmps, fmp, next);
+	data.ptr = fmp;
+	ret = mlx5_l3t_set_entry(priv->mtr_profile_tbl,
+				 meter_profile_id, &data);
+	if (ret)
+		return -rte_mtr_error_set(error, ENOTSUP,
+					  RTE_MTR_ERROR_TYPE_UNSPECIFIED,
+					  NULL, "Meter profile insert fail.");
 	return 0;
 error:
 	mlx5_free(fmp);
@@ -472,8 +484,10 @@ mlx5_flow_meter_profile_delete(struct rte_eth_dev *dev,
 		return -rte_mtr_error_set(error, EBUSY,
 					  RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
 					  NULL, "Meter profile is in use.");
-	/* Remove from list. */
-	TAILQ_REMOVE(&priv->flow_meter_profiles, fmp, next);
+	if (mlx5_l3t_clear_entry(priv->mtr_profile_tbl, meter_profile_id))
+		return -rte_mtr_error_set(error, EBUSY,
+					  RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
+					  NULL, "Meter profile remove fail.");
 	mlx5_free(fmp);
 	return 0;
 }
@@ -1859,7 +1873,6 @@ mlx5_flow_meter_flush(struct rte_eth_dev *dev, struct rte_mtr_error *error)
 {
 	struct mlx5_priv *priv = dev->data->dev_private;
 	struct mlx5_legacy_flow_meters *fms = &priv->flow_meters;
-	struct mlx5_mtr_profiles *fmps = &priv->flow_meter_profiles;
 	struct mlx5_flow_meter_profile *fmp;
 	struct mlx5_legacy_flow_meter *legacy_fm;
 	struct mlx5_flow_meter_info *fm;
@@ -1921,12 +1934,18 @@ mlx5_flow_meter_flush(struct rte_eth_dev *dev, struct rte_mtr_error *error)
 		mlx5_l3t_destroy(priv->sh->mtrmng->policy_idx_tbl);
 		priv->sh->mtrmng->policy_idx_tbl = NULL;
 	}
-	TAILQ_FOREACH_SAFE(fmp, fmps, next, tmp) {
-		/* Check unused. */
-		MLX5_ASSERT(!fmp->ref_cnt);
-		/* Remove from list. */
-		TAILQ_REMOVE(&priv->flow_meter_profiles, fmp, next);
-		mlx5_free(fmp);
+	if (priv->mtr_profile_tbl) {
+		MLX5_L3T_FOREACH(priv->mtr_profile_tbl, i, entry) {
+			fmp = entry;
+			if (mlx5_flow_meter_profile_delete(dev, fmp->id,
+							   error))
+				return -rte_mtr_error_set(error, EINVAL,
+					RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
+						NULL, "Fail to destroy "
+						"meter profile.");
+		}
+		mlx5_l3t_destroy(priv->mtr_profile_tbl);
+		priv->mtr_profile_tbl = NULL;
 	}
 	/* Delete default policy table. */
 	mlx5_flow_destroy_def_policy(dev);
diff --git a/drivers/net/mlx5/windows/mlx5_os.c b/drivers/net/mlx5/windows/mlx5_os.c
index 3fe3f55f49..e30b682822 100644
--- a/drivers/net/mlx5/windows/mlx5_os.c
+++ b/drivers/net/mlx5/windows/mlx5_os.c
@@ -566,7 +566,9 @@ mlx5_dev_spawn(struct rte_device *dpdk_dev,
 	priv->flows = 0;
 	priv->ctrl_flows = 0;
 	TAILQ_INIT(&priv->flow_meters);
-	TAILQ_INIT(&priv->flow_meter_profiles);
+	priv->mtr_profile_tbl = mlx5_l3t_create(MLX5_L3T_TYPE_PTR);
+	if (!priv->mtr_profile_tbl)
+		goto error;
 	/* Bring Ethernet device up. */
 	DRV_LOG(DEBUG, "port %u forcing Ethernet interface up.",
 		eth_dev->data->port_id);
@@ -644,6 +646,8 @@ mlx5_dev_spawn(struct rte_device *dpdk_dev,
 	return eth_dev;
 error:
 	if (priv) {
+		if (priv->mtr_profile_tbl)
+			mlx5_l3t_destroy(priv->mtr_profile_tbl);
 		if (own_domain_id)
 			claim_zero(rte_eth_switch_domain_free(priv->domain_id));
 		mlx5_free(priv);
-- 
2.20.0


  reply	other threads:[~2021-07-02  9:15 UTC|newest]

Thread overview: 6+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2021-07-02  9:14 [dpdk-dev] [PATCH v1 0/4] ASO meter sharing support Shun Hao
2021-07-02  9:14 ` Shun Hao [this message]
2021-07-02  9:14 ` [dpdk-dev] [PATCH v1 2/4] net/mlx5: fix meter policy ID table container Shun Hao
2021-07-02  9:14 ` [dpdk-dev] [PATCH v1 3/4] net/mlx5: fix meter flow direction check Shun Hao
2021-07-02  9:14 ` [dpdk-dev] [PATCH v1 4/4] net/mlx5: fix meter policy flow match item Shun Hao
2021-07-06  7:45 ` [dpdk-dev] [PATCH v1 0/4] ASO meter sharing support Raslan Darawsheh

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20210702091446.24635-2-shunh@nvidia.com \
    --to=shunh@nvidia.com \
    --cc=dev@dpdk.org \
    --cc=matan@nvidia.com \
    --cc=orika@nvidia.com \
    --cc=rasland@nvidia.com \
    --cc=roniba@nvidia.com \
    --cc=shahafs@nvidia.com \
    --cc=thomas@monjalon.net \
    --cc=viacheslavo@nvidia.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).