Subject: [dts][V1] test_plans/*: modify power test plans to adapt meson build
Date: Tue, 1 Mar 2022 12:22:39 +0000 [thread overview]
Message-ID: <20220301122239.812405-1-tadhg.kearney@intel.com> (raw)
[-- Warning: decoded text below may be mangled, UTF-8 assumed --]
[-- Attachment #1: Type: text/plain; charset=y, Size: 14213 bytes --]
Signed-off-by: Tadhg Kearney <tadhg.kearney@intel.com>
---
.../power_bidirection_channel_test_plan.rst | 8 +++----
test_plans/power_branch_ratio_test_plan.rst | 4 ++--
test_plans/power_empty_poll_test_plan.rst | 4 ++--
test_plans/power_negative_test_plan.rst | 12 +++++-----
test_plans/power_pbf_test_plan.rst | 6 ++---
test_plans/power_pstate_test_plan.rst | 2 +-
test_plans/power_telemetry_test_plan.rst | 2 +-
test_plans/vm_power_manager_test_plan.rst | 6 ++---
test_plans/vm_pw_mgmt_policy_test_plan.rst | 22 +++++++++++--------
9 files changed, 35 insertions(+), 31 deletions(-)
diff --git a/test_plans/power_bidirection_channel_test_plan.rst b/test_plans/power_bidirection_channel_test_plan.rst
index a6df6597..59bd193d 100644
--- a/test_plans/power_bidirection_channel_test_plan.rst
+++ b/test_plans/power_bidirection_channel_test_plan.rst
@@ -59,7 +59,7 @@ Step 1. Launch VM using libvirt::
Step 2. Launch VM power manager example on the host to monitor the channel from VM::
- ./examples/vm_power_manager/build/vm_power_mgr -c 0xfffe -n 4 --no-pci
+ ./<build_target>/examples/dpdk-vm_power_manager -c 0xfffe -n 4 --no-pci
vmpower> add_vm [vm name]
vmpower> add_channels [vm name] all
vmpower> set_channel_status [vm name] all enabled
@@ -73,7 +73,7 @@ Step 2. Launch VM power manager example on the host to monitor the channel from
Step 3. In the VM, launch guest_vm_power_mgr to set and send the power manager policy to the host power example::
- ./examples/vm_power_manager/guest_cli/build/guest_vm_power_mgr -c 0xfe -n 4 -m 1024 --no-pci --file-prefix=vm_power -- --vm-name=ubuntu --vcpu-list=0-7
+ ./<build_target>/examples/dpdk-guest_cli -c 0xfe -n 4 -m 1024 --no-pci --file-prefix=vm_power -- --vm-name=ubuntu --vcpu-list=0-7
Send command to the core 7 on host APP:
vmpower(guest)> set_cpu_freq 7 down
@@ -100,7 +100,7 @@ Step 1. Launch VM using libvirt::
Step 2. Launch VM power manager example on the host to monitor the channel from VM::
- ./examples/vm_power_manager/build/vm_power_mgr -c 0xfffe -n 4 --no-pci
+ ./<build_target>/examples/dpdk-vm_power_manager -c 0xfffe -n 4 --no-pci
vmpower> add_vm [vm name]
vmpower> add_channels [vm name] all
vmpower> set_channel_status [vm name] all enabled
@@ -115,7 +115,7 @@ Step 3. Enable the query permission for target VM from host vm_power_mgr example
Step 4. Query the CPU frequency for all CPU cores from VM side::
- ./examples/vm_power_manager/guest_cli/build/guest_vm_power_mgr -c 0xfe -n 4 -m 1024 --no-pci --file-prefix=vm_power -- --vm-name=ubuntu --vcpu-list=0-7
+ ./<build_target>/examples/dpdk-guest_cli -c 0xfe -n 4 -m 1024 --no-pci --file-prefix=vm_power -- --vm-name=ubuntu --vcpu-list=0-7
vmpower> query_cpu_freq <core_num> | all
Check vcpu 0~7 frequency info will be returned, for example:
diff --git a/test_plans/power_branch_ratio_test_plan.rst b/test_plans/power_branch_ratio_test_plan.rst
index daecc133..17553068 100644
--- a/test_plans/power_branch_ratio_test_plan.rst
+++ b/test_plans/power_branch_ratio_test_plan.rst
@@ -58,11 +58,11 @@ no_turbo_max=$(rdmsr -p 2 0x0CE -f 15:8 -d)00000
Test Case 1 : Set Branch-Ratio Test Rate by User ====================================================================================
1. Launch VM power manager sample on the host to run branch monitor.
-./x86_64-native-linuxapp-gcc/examples/dpdk-vm_power_manager -v -c 0xe -n 1 -m 1024 --no-pci -- --core-branch-ratio=1-3:0.3
+./<build_target>/examples/dpdk-vm_power_manager -v -c 0xe -n 1 -m 1024 --no-pci -- --core-branch-ratio=1-3:0.3
2. Launch testpmd with fwd io mode::
- ./x86_64-native-linuxapp-gcc/app/dpdk-testpmd -v -c 0x6 -n 1 -m 1024 --file-prefix=vmpower2 -- -i
+ ./<build_target>/app/dpdk-testpmd -v -c 0x6 -n 1 -m 1024 --file-prefix=vmpower2 -- -i
> start
3. Inject packet with packet generator to the NIC, with line rate,
diff --git a/test_plans/power_empty_poll_test_plan.rst b/test_plans/power_empty_poll_test_plan.rst
index 44728308..f18a483a 100644
--- a/test_plans/power_empty_poll_test_plan.rst
+++ b/test_plans/power_empty_poll_test_plan.rst
@@ -124,7 +124,7 @@ Test Case1 : Basic Training mode test based on one NIC with l3fwd-power
=======================================================================
Step 1. Bind One NIC to DPDK driver, launch l3fwd-power with empty-poll enabled
- ./l3fwd-power -l 1-2 -n 4 -- -p 0x1 -P --config="(0,0,2)" --empty-poll="1,0,0" -l 10 -m 6 -h 1
+ ./<build_target>/examples/dpdk-l3fwd-power -l 1-2 -n 4 -- -p 0x1 -P --config="(0,0,2)" --empty-poll="1,0,0" -l 10 -m 6 -h 1
Step 2. Check the log also when changing the inject packet rate as following:
@@ -139,6 +139,6 @@ Test Case2: No-Training mode test based on one NIC with l3fwd-power
===================================================================
Step 1. Bind One NIC to DPDK driver, launch l3fwd-power with empty-poll enabled
- ./l3fwd-power -l 1-2 -n 4 -- -p 0x1 -P --config="(0,0,2)" --empty-poll="0,350000,500000" -l 10 -m 6 -h 1
+ ./<build_target>/examples/dpdk-l3fwd-power -l 1-2 -n 4 -- -p 0x1 -P --config="(0,0,2)" --empty-poll="0,350000,500000" -l 10 -m 6 -h 1
Step 2. Check no training steps are executed in sample's launch log.
diff --git a/test_plans/power_negative_test_plan.rst b/test_plans/power_negative_test_plan.rst
index 76563683..3d074832 100644
--- a/test_plans/power_negative_test_plan.rst
+++ b/test_plans/power_negative_test_plan.rst
@@ -53,7 +53,7 @@ Step 1. Create powermonitor fold for vm_power_manager sample::
Step 2. Luanch VM power manager sample::
- ./examples/vm_power_manager/build/vm_power_mgr -l 1-3 -n 4 --file-prefix=test1 --no-pci
+ ./<build_target>/examples/dpdk-vm_power_manager -l 1-3 -n 4 --file-prefix=test1 --no-pci
Step 3. Prepare policy in JSON format then send it to the fifo channel:
Prepare different command in JSON format then send it to the fifo channel
@@ -84,7 +84,7 @@ Step 1. Create powermonitor fold for vm_power_manager sample::
Step 2. Luanch VM power manager sample::
- ./examples/vm_power_manager/build/vm_power_mgr -l 1-3 -n 4 --file-prefix=test1 --no-pci
+ ./<build_target>/examples/dpdk-vm_power_manager -l 1-3 -n 4 --file-prefix=test1 --no-pci
Step 3. Prepare policy in JSON format then send it to the fifo channel:
@@ -118,7 +118,7 @@ Note: For the VM xml file which will be used for creating the VM, it can re-use
Step 2. Luanch VM power manager sample on the host to monitor the channel from VM::
- ./examples/vm_power_manager/build/vm_power_mgr -l 12-14 -n 4 --no-pci
+ ./<build_taget>/examples/dpdk-vm_power_manager -l 12-14 -n 4 --no-pci
> add_vm [vm name]
> add_channels [vm name] all
> set_channel_status [vm name] all enabled
@@ -133,7 +133,7 @@ Check point: No crash should be occur at vm_power_mgr sample
Step 3. In the VM, launch guest_vm_power_mgr to set and send the power manager policy to the host power sample::
- ./examples/vm_power_manager/guest_cli/build/guest_vm_power_mgr -c 0xff -n 4 -m 1024 --no-pci --file-prefix=yaolei \
+ ./<build_target>/examples/dpdk-guest_cli -c 0xff -n 4 -m 1024 --no-pci --file-prefix=yaolei \
-- --vm-name=ubuntu --vcpu-list=0-7
> set_cpu_freq 128 down
> set_cpu_freq 1000000000000 down
@@ -149,11 +149,11 @@ Test Case4: TRAFFIC Policy Test based on JSON configure file with large integer
Step 1. Generate 1 VF under vfio-pci driver, launch vm_power_mgr sample with PF, for example::
echo 1 > /sys/bus/pci/drivers/vfio-pci/0000\:82\:00.0/max_vfs
- ./examples/vm_power_manager/build/vm_power_mgr -l 1-4 -n 4 --socket-mem=1024,1024 --file-prefix=test1 -a 82:00.0 -- -p 0x01
+ ./<build_target>/examples/dpdk-vm_power_manager -l 1-4 -n 4 --socket-mem=1024,1024 --file-prefix=test1 -a 82:00.0 -- -p 0x01
Step 2. Launch testpmd with VF::
- ./x86_64-native-linuxapp-gcc/app/testpmd -l 5-6 -n 4 --socket-mem=1024,1024 --file-prefix=test2 -a 0000:82:02.0 -- -i
+ ./<build_target>/app/dpdk-testpmd -l 5-6 -n 4 --socket-mem=1024,1024 --file-prefix=test2 -a 0000:82:02.0 -- -i
> set fwd macswap
> start
diff --git a/test_plans/power_pbf_test_plan.rst b/test_plans/power_pbf_test_plan.rst
index 6a38fc61..8131bc5b 100644
--- a/test_plans/power_pbf_test_plan.rst
+++ b/test_plans/power_pbf_test_plan.rst
@@ -59,7 +59,7 @@ Step 1. Create powermonitor fold for::
Step 2. Compile DPDK with Power Lib debug info on, then Luanch VM power manager sample::
- ./examples/vm_power_manager/build/vm_power_mgr -l 1-46 -n 4 --file-prefix=power --no-pci
+ ./<build_target>/examples/dpdk-vm_power_manager -l 1-46 -n 4 --file-prefix=power --no-pci
Check two different base_max frequency will be shown in log, for example on Intel 6230N Processor:
The log will be like as following
@@ -87,7 +87,7 @@ Step 1. Create powermonitor fold for::
Step 2. Compile DPDK with Power Lib debug info on, then aunch VM power manager sample::
- ./examples/vm_power_manager/build/vm_power_mgr -l 1-46 -n 4 --file-prefix=power --no-pci
+ ./<build_target>/examples/dpdk-vm_power_manager -l 1-46 -n 4 --file-prefix=power --no-pci
Step 3. Prepare different command in JSON format::
@@ -129,7 +129,7 @@ Step 1. Create powermonitor fold for::
Step 2. Compile DPDK with Power Lib debug info on, then launch VM power manager sample::
- ./examples/vm_power_manager/build/vm_power_mgr -l 1-46 -n 4 --file-prefix=power --no-pci
+ ./<build_target>/examples/dpdk-vm_power_manager -l 1-46 -n 4 --file-prefix=power --no-pci
Step 3. Prepare Several command in JSON format then send it to the fifo channel for the high priority core::
diff --git a/test_plans/power_pstate_test_plan.rst b/test_plans/power_pstate_test_plan.rst
index f2a5e199..ce79c71f 100644
--- a/test_plans/power_pstate_test_plan.rst
+++ b/test_plans/power_pstate_test_plan.rst
@@ -64,7 +64,7 @@ Step 1. Create powermonitor fold for::
Step 2. Luanch VM power manager sample::
- ./examples/vm_power_manager/build/vm_power_mgr -l 1-4 -n 4 --file-prefix=power --no-pci
+ ./<build_target>/examples/dpdk-vm_power_manager -l 1-4 -n 4 --file-prefix=power --no-pci
Step 3. Prepare different command in JSON format then send it to the fifo channel::
diff --git a/test_plans/power_telemetry_test_plan.rst b/test_plans/power_telemetry_test_plan.rst
index fd27f8a1..0afb0f77 100644
--- a/test_plans/power_telemetry_test_plan.rst
+++ b/test_plans/power_telemetry_test_plan.rst
@@ -63,7 +63,7 @@ Test Case 1 : Check all 3 type of power related info reported by Telemetry Syste
=================================================================================
1. Launch l3fwd-power sample with telemetry enabled, bind one NIC to DPDK driver, launch l3fwd-power::
- ./l3fwd-power -l 1-2 -n 4 --telemetry -- -p 0x1 -P --config="(0,0,2)" --telemetry
+ ./<build_target>/examples/dpdk-l3fwd-power -l 1-2 -n 4 --telemetry -- -p 0x1 -P --config="(0,0,2)" --telemetry
2. Get the telemetry info using dpdk-telemetry-client.py script, then choose mode 3 ``Send for global Metrics``::
diff --git a/test_plans/vm_power_manager_test_plan.rst b/test_plans/vm_power_manager_test_plan.rst
index 7cac509c..58e78949 100644
--- a/test_plans/vm_power_manager_test_plan.rst
+++ b/test_plans/vm_power_manager_test_plan.rst
@@ -123,11 +123,11 @@ Test Case 1: VM Power Management Channel
3. Run power-manager in Host::
- ./build/vm_power_mgr -c 0x3 -n 4
+ ./<build_target>/examples/dpdk-vm_power_manager -c 0x3 -n 4
4. Startup VM and run guest_vm_power_mgr::
- guest_vm_power_mgr -c 0x1f -n 4 -- -i
+ ./<build_target>/examples/dpdk-guest_cli -c 0x1f -n 4 -- -i
5. Add vm in host and check vm_power_mgr can get frequency normally::
@@ -155,7 +155,7 @@ Test Case 1: VM Power Management Channel
7. Run vm_power_mgr in vm::
- guest_cli/build/vm_power_mgr -c 0x1f -n 4
+ ./<build_target>/examples/dpdk-vm_power_manager -c 0x1f -n 4
Check monitor channel for all cores has been connected.
diff --git a/test_plans/vm_pw_mgmt_policy_test_plan.rst b/test_plans/vm_pw_mgmt_policy_test_plan.rst
index 98894ff5..e751649e 100644
--- a/test_plans/vm_pw_mgmt_policy_test_plan.rst
+++ b/test_plans/vm_pw_mgmt_policy_test_plan.rst
@@ -168,11 +168,13 @@ Set up testing environment
#. Compile and run power-manager in host, core number should >= 3, add vm in host.
- export RTE_SDK=`pwd`
- export RTE_TARGET=x86_64-native-linuxapp-gcc
- make -C examples/vm_power_manager
+ CC=gcc meson -Denable_kmods=True -Dlibdir=lib --default-library=static <build_target>
+ ninja -C <build_target>
- ./examples/vm_power_manager/build/vm_power_mgr -c 0xffff -n 4
+ meson configure -Dexamples=vm_power_manager <build_target>
+ ninja -C <build_target>
+
+ ./<build_target>/examples/dpdk-vm_power_manager -c 0xffff -n 4
vmpower> add_vm <vm_name>
vmpower> add_channels <vm_name> all
@@ -181,7 +183,7 @@ Set up testing environment
#. Run testpmd on vm0 when do traffic policy testing, other test cases ignore
this step.
- ./testpmd -c 0x3 -n 1 -v -m 1024 --file-prefix=vmpower1 -- -i --port-topology=loop
+ ./<build_target>/app/dpdk-testpmd -c 0x3 -n 1 -v -m 1024 --file-prefix=vmpower1 -- -i --port-topology=loop
testpmd> set fwd mac
testpmd> set promisc all on
@@ -190,11 +192,13 @@ Set up testing environment
#. Compile and run guest_vm_power_mgr on VM.
- export RTE_SDK=`pwd`
- export RTE_TARGET=x86_64-native-linuxapp-gcc
- make -C examples/vm_power_manager/guest_cli
+ CC=gcc meson -Denable_kmods=True -Dlibdir=lib --default-library=static <build_target>
+ ninja -C <build_target>
+
+ meson configure -Dexamples=vm_power_manager/guest_cli <build_target>
+ ninja -C <build_target>
- ./examples/vm_power_manager/guest_cli/build/guest_vm_power_mgr \
+ ./<build_target>/examples/dpdk-guest_cli \
-c 0xff -n 4 --file-prefix=vmpower2 -- -i --vm-name=<vm name> \
--policy=<policy name> --vcpu-list=<vcpus list> --busy-hours=<time stage>
--
2.25.1
[-- Attachment #2.1: Type: text/plain, Size: 505 bytes --]
--------------------------------------------------------------
Intel Research and Development Ireland Limited
Registered in Ireland
Registered Office: Collinstown Industrial Park, Leixlip, County Kildare
Registered Number: 308263
This e-mail and any attachments may contain confidential material for the sole
use of the intended recipient(s). Any review or distribution by others is
strictly prohibited. If you are not the intended recipient, please contact the
sender and delete all copies.
[-- Attachment #2.2: Type: text/html, Size: 546 bytes --]
reply other threads:[~2022-03-01 12:22 UTC|newest]
Thread overview: [no followups] expand[flat|nested] mbox.gz Atom feed
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=20220301122239.812405-1-tadhg.kearney@intel.com \
--to=tadhg.kearney@intel.com \
--cc=dts@dpdk.org \
--cc=reshma.pattan@intel.com \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).