When creating internal transfer flow on root table with lowerest
priority, the flow was created with max UINT32_MAX priority. It is wrong
since the flow is created in kernel and max priority supported is 16.
This patch fixes this by adding internal flow check.
Fixes: 5f8ae44dd454 ("net/mlx5: enlarge maximal flow priority")
Cc: stable@dpdk.org
Signed-off-by: Xueming Li <xuemingl@nvidia.com>
Acked-by: Viacheslav Ovsiienko <viacheslavo@nvidia.com>
---
drivers/net/mlx5/mlx5_flow.c | 7 ++++++-
drivers/net/mlx5/mlx5_flow.h | 4 ++--
drivers/net/mlx5/mlx5_flow_dv.c | 3 ++-
3 files changed, 10 insertions(+), 4 deletions(-)
diff --git a/drivers/net/mlx5/mlx5_flow.c b/drivers/net/mlx5/mlx5_flow.c
index ffcc031bff3..4abeae8ce2d 100644
--- a/drivers/net/mlx5/mlx5_flow.c
+++ b/drivers/net/mlx5/mlx5_flow.c
@@ -1003,13 +1003,15 @@ mlx5_get_lowest_priority(struct rte_eth_dev *dev,
* Pointer to device flow rule attributes.
* @param[in] subpriority
* The priority based on the items.
+ * @param[in] external
+ * Flow is user flow.
* @return
* The matcher priority of the flow.
*/
uint16_t
mlx5_get_matcher_priority(struct rte_eth_dev *dev,
const struct rte_flow_attr *attr,
- uint32_t subpriority)
+ uint32_t subpriority, bool external)
{
uint16_t priority = (uint16_t)attr->priority;
struct mlx5_priv *priv = dev->data->dev_private;
@@ -1018,6 +1020,9 @@ mlx5_get_matcher_priority(struct rte_eth_dev *dev,
if (attr->priority == MLX5_FLOW_LOWEST_PRIO_INDICATOR)
priority = priv->config.flow_prio - 1;
return mlx5_os_flow_adjust_priority(dev, priority, subpriority);
+ } else if (!external && attr->transfer && attr->group == 0 &&
+ attr->priority == MLX5_FLOW_LOWEST_PRIO_INDICATOR) {
+ return (priv->config.flow_prio - 1) * 3;
}
if (attr->priority == MLX5_FLOW_LOWEST_PRIO_INDICATOR)
priority = MLX5_NON_ROOT_FLOW_MAX_PRIO;
diff --git a/drivers/net/mlx5/mlx5_flow.h b/drivers/net/mlx5/mlx5_flow.h
index c25af8d9864..f1a83d537d0 100644
--- a/drivers/net/mlx5/mlx5_flow.h
+++ b/drivers/net/mlx5/mlx5_flow.h
@@ -1431,8 +1431,8 @@ uint32_t mlx5_flow_adjust_priority(struct rte_eth_dev *dev, int32_t priority,
uint32_t mlx5_get_lowest_priority(struct rte_eth_dev *dev,
const struct rte_flow_attr *attr);
uint16_t mlx5_get_matcher_priority(struct rte_eth_dev *dev,
- const struct rte_flow_attr *attr,
- uint32_t subpriority);
+ const struct rte_flow_attr *attr,
+ uint32_t subpriority, bool external);
int mlx5_flow_get_reg_id(struct rte_eth_dev *dev,
enum mlx5_feature_name feature,
uint32_t id,
diff --git a/drivers/net/mlx5/mlx5_flow_dv.c b/drivers/net/mlx5/mlx5_flow_dv.c
index e505cdbb0f7..6413b45d8d3 100644
--- a/drivers/net/mlx5/mlx5_flow_dv.c
+++ b/drivers/net/mlx5/mlx5_flow_dv.c
@@ -13556,7 +13556,8 @@ flow_dv_translate(struct rte_eth_dev *dev,
matcher.crc = rte_raw_cksum((const void *)matcher.mask.buf,
matcher.mask.size);
matcher.priority = mlx5_get_matcher_priority(dev, attr,
- matcher.priority);
+ matcher.priority,
+ dev_flow->external);
/**
* When creating meter drop flow in drop table, using original
* 5-tuple match, the matcher priority should be lower than
--
2.33.0