* Seg-fault crash with the VF removal on Azure VM
@ 2025-06-30 16:34 madhukar mythri
  0 siblings, 0 replies; only message in thread
From: madhukar mythri @ 2025-06-30 16:34 UTC (permalink / raw)
  To: users

[-- Attachment #1: Type: text/plain, Size: 895 bytes --]

Hi,

We are facing a Seg-fault crash issue on our DPDK application with
"failsafe" PMD on Azure VM, when we toggle the Azure "Accelerated
networking" option.


On the running VM, when we toggle(disable/enable) the "Accelerated
networking" option, then we could see the respective SRIOV VF device was
removed and added back, at this time our DPDK application got crashed while
doing Rx "failsafe_rx_burst_fast()" operation.


As per the DPDK "failsafe" PMD design the hotplug is supported and even
after the primary SRIOV VF device is removed, the application can run Rx/Tx
operations seamlessly on the other sub-device("netvsc"). But, this is not
happening.


Does anybody tested this hot-plug functionality on Azure VM and hot-plug
works well on DPDK apps ?

Any known issues/limitations on the "failsafe" PMD hot-plug ?


DPDK-version: 23.11

Linux kernel-version: 5.15.0


Thanks,

Madhukar.

[-- Attachment #2: Type: text/html, Size: 6412 bytes --]

^ permalink raw reply	[flat|nested] only message in thread

only message in thread, other threads:[~2025-06-30 16:34 UTC | newest]

Thread overview: (only message) (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2025-06-30 16:34 Seg-fault crash with the VF removal on Azure VM madhukar mythri

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).