From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Received: from mx0a-0016ce01.pphosted.com (mx0a-0016ce01.pphosted.com [67.231.148.157]) by dpdk.org (Postfix) with ESMTP id A82AD8E81 for ; Sat, 12 Sep 2015 02:43:44 +0200 (CEST) Received: from pps.filterd (m0045602.ppops.net [127.0.0.1]) by mx0a-0016ce01.pphosted.com (8.15.0.59/8.15.0.59) with SMTP id t8C0hcBf018081 for ; Fri, 11 Sep 2015 17:43:43 -0700 Received: from avcashub1.qlogic.com (avcashub1.qlogic.com [198.70.193.115]) by mx0a-0016ce01.pphosted.com with ESMTP id 1wqyhvsqr4-2 (version=TLSv1/SSLv3 cipher=AES128-SHA bits=128 verify=NOT) for ; Fri, 11 Sep 2015 17:43:43 -0700 Received: from avluser05.qlc.com (10.1.113.115) by qlc.com (10.1.4.190) with Microsoft SMTP Server id 14.3.235.1; Fri, 11 Sep 2015 17:43:43 -0700 Received: (from rmody@localhost) by avluser05.qlc.com (8.14.4/8.14.4/Submit) id t8C0hhFb020871; Fri, 11 Sep 2015 17:43:43 -0700 X-Authentication-Warning: avluser05.qlc.com: rmody set sender to rasesh.mody@qlogic.com using -f From: Rasesh Mody To: Date: Fri, 11 Sep 2015 17:42:55 -0700 Message-ID: <1442018576-19981-5-git-send-email-rasesh.mody@qlogic.com> X-Mailer: git-send-email 1.7.10.3 In-Reply-To: <1442018576-19981-1-git-send-email-rasesh.mody@qlogic.com> References: <1442018576-19981-1-git-send-email-rasesh.mody@qlogic.com> MIME-Version: 1.0 Content-Type: text/plain X-Proofpoint-Virus-Version: vendor=nai engine=5700 definitions=7921 signatures=670636 X-Proofpoint-Spam-Details: rule=notspam policy=default score=0 spamscore=0 suspectscore=1 malwarescore=0 phishscore=0 adultscore=0 bulkscore=0 classifier=spam adjust=0 reason=mlx scancount=1 engine=8.0.1-1507310000 definitions=main-1509120011 Cc: sony.chacko@qlogic.com Subject: [dpdk-dev] [PATCH 4/5] doc: Add BNX2X PMD documentation X-BeenThere: dev@dpdk.org X-Mailman-Version: 2.1.15 Precedence: list List-Id: patches and discussions about DPDK List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , X-List-Received-Date: Sat, 12 Sep 2015 00:43:45 -0000 From: Harish Patil Signed-off-by: Harish Patil --- doc/guides/nics/bnx2x.rst | 324 +++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 324 insertions(+) create mode 100644 doc/guides/nics/bnx2x.rst diff --git a/doc/guides/nics/bnx2x.rst b/doc/guides/nics/bnx2x.rst new file mode 100644 index 0000000..613a2b7 --- /dev/null +++ b/doc/guides/nics/bnx2x.rst @@ -0,0 +1,324 @@ +.. BSD LICENSE + Copyright (c) 2015 QLogic Corporation + All rights reserved. + + Redistribution and use in source and binary forms, with or without + modification, are permitted provided that the following conditions + are met: + + * Redistributions of source code must retain the above copyright + notice, this list of conditions and the following disclaimer. + * Redistributions in binary form must reproduce the above copyright + notice, this list of conditions and the following disclaimer in + the documentation and/or other materials provided with the + distribution. + * Neither the name of QLogic Corporation nor the names of its + contributors may be used to endorse or promote products derived + from this software without specific prior written permission. + + THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS + "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT + LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR + A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT + OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, + SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT + LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, + DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY + THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT + (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE + OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. + +BNX2X Poll Mode Driver +====================== + +The BNX2X poll mode driver library (**librte_pmd_bnx2x**) implemements support +for **QLogic 578xx** 10/20 Gbps family of adapters as well as their virtual +functions (VF) in SR-IOV context. It is supported on several standard Linux +distros like Red Hat 7.x and SLES12 OS. It is compile-tested under FreeBSD OS. + +More information can be found at `QLogic Corporation's Official Website +`_. + +Supported Features +------------------ + +BNX2X PMD has support for: + +- Base L2 features +- Unicast/multicast filtering +- Promiscuous mode +- Port hardware statistics +- SR-IOV VF + +Non-supported Features +---------------------- + +The features not yet supported include: + +- TSS (Transmit Side Scaling) +- RSS (Receive Side Scaling) +- LRO/TSO offload +- Checksum offload +- SR-IOV PF + +Co-existence considerations +--------------------------- + +- BCM578xx being a CNA can have both NIC and Storage personalities. +However, coexistence with storage protocol drivers (cnic, bnx2fc and +bnx2fi) is not supported on the same adapter. So storage personality +has to be disabled on that adapter when used in DPDK applications. + +- For SR-IOV case, bnx2x PMD will be used to bind to SR-IOV VF device and +linux native kernel driver (bnx2x) will be attached to SR-IOV PF. + + +Supported QLogic NICs +--------------------- + +- 578xx + +Prerequisites +------------- + +- Requires firmware version **7.2.51.0**. It is inbox on most of the + standard linux distros. If it is not available visit + `QLogic Driver Download Center ` + to get the required firmware. + +Pre-Installation Configuration +------------------------------ + +Config File Options +~~~~~~~~~~~~~~~~~~~ + +The following options can be modified in the ``.config`` file. Please note that +enabling debugging options may affect system performance. + +- ``CONFIG_RTE_LIBRTE_BNX2X_PMD`` (default **y**) + + Toggle compilation of bnx2x driver. + +- ``CONFIG_RTE_LIBRTE_BNX2X_DEBUG`` (default **n**) + + Toggle display of generic debugging messages. + +- ``CONFIG_RTE_LIBRTE_BNX2X_DEBUG_INIT`` (default **n**) + + Toggle display of initialization related messages. + +- ``CONFIG_RTE_LIBRTE_BNX2X_DEBUG_TX`` (default **n**) + + Toggle display of transmit fast path run-time messages. + +- ``CONFIG_RTE_LIBRTE_BNX2X_DEBUG_RX`` (default **n**) + + Toggle display of receive fast path run-time messages. + +- ``CONFIG_RTE_LIBRTE_BNX2X_REG_ACCESS`` (default **n**) + + Toggle display of register reads and writes. + + +.. _driver-compilation: + +Driver Compilation +~~~~~~~~~~~~~~~~~~ + +To compile BNX2X PMD for Linux x86_64 gcc target, run the following "make" +command: + +.. code-block:: console + + cd + make config T=x86_64-native-linuxapp-gcc install + +To compile BNX2X PMD for Linux x86_64 clang target, run the following "make" +command: + +.. code-block:: console + + cd + make config T=x86_64-native-linuxapp-clang install + +To compile BNX2X PMD for FreeBSD x86_64 clang target, run the following "gmake" +command: + +.. code-block:: console + + cd + gmake config T=x86_64-native-bsdapp-clang install + +Linux +----- + +.. _linux-installation: + +Linux Installation +~~~~~~~~~~~~~~~~~~ + +Sample Application Notes +~~~~~~~~~~~~~~~~~~~~~~~~ + +This section demonstrates how to launch **testpmd** with QLogic 578xx +devices managed by librte_pmd_bnx2x in Linux operating system. + +#. Request huge pages: + + .. code-block:: console + + echo 1024 > /sys/kernel/mm/hugepages/hugepages-2048kB/nr_hugepages/nr_hugepages + +#. Load igb_uio or vfio-pci driver: + + .. code-block:: console + + insmod ./x86_64-native-linuxapp-gcc/kmod/igb_uio.ko + + or + + .. code-block:: console + + modprobe vfio-pci + +#. Bind the QLogic adapters to igb_uio or vfio-pci loaded in the previous + step: + + .. code-block:: console + + ./tools/dpdk_nic_bind.py --bind igb_uio 0000:84:00.0 0000:84:00.1 + + or + + Setup VFIO permissions for regular users and then bind to vfio-pci: + + .. code-block:: console + + sudo chmod a+x /dev/vfio + + sudo chmod 0666 /dev/vfio/* + + ./tools/dpdk_nic_bind.py --bind vfio-pci 0000:84:00.0 0000:84:00.1 + +#. Start testpmd with basic parameters: + + .. code-block:: console + + ./x86_64-native-linuxapp-gcc/app/testpmd -c 0xf -n 4 -- -i + + Example output: + + .. code-block:: console + + [...] + EAL: PCI device 0000:84:00.0 on NUMA socket 1 + EAL: probe driver: 14e4:168e rte_bnx2x_pmd + EAL: PCI memory mapped at 0x7f14f6fe5000 + EAL: PCI memory mapped at 0x7f14f67e5000 + EAL: PCI memory mapped at 0x7f15fbd9b000 + EAL: PCI device 0000:84:00.1 on NUMA socket 1 + EAL: probe driver: 14e4:168e rte_bnx2x_pmd + EAL: PCI memory mapped at 0x7f14f5fe5000 + EAL: PCI memory mapped at 0x7f14f57e5000 + EAL: PCI memory mapped at 0x7f15fbd4f000 + Interactive-mode selected + Configuring Port 0 (socket 0) + PMD: bnx2x_dev_tx_queue_setup(): fp[00] req_bd=512, thresh=512, usable_bd=1020, total_bd=1024, tx_pages=4 + PMD: bnx2x_dev_rx_queue_setup(): fp[00] req_bd=128, thresh=0, usable_bd=510, total_bd=512, rx_pages=1, cq_pages=8 + PMD: bnx2x_print_adapter_info(): + [...] + Checking link statuses... + Port 0 Link Up - speed 10000 Mbps - full-duplex + Port 1 Link Up - speed 10000 Mbps - full-duplex + Done + testpmd> + +SR-IOV: Prerequistes and sample Application Notes +~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ + +This section provides instructions to configure SR-IOV with Linux OS. + +#. Verify SR-IOV and ARI capabilities are enabled on the adapter using lspci: + + .. code-block:: console + + lspci -s -vvv + + Example output: + + .. code-block:: console + + [...] + Capabilities: [1b8 v1] Alternative Routing-ID Interpretation (ARI) + [...] + Capabilities: [1c0 v1] Single Root I/O Virtualization (SR-IOV) + [...] + Kernel driver in use: igb_uio + +#. Load the kernel module: + + .. code-block:: console + + modprobe bnx2x + + Example output: + + .. code-block:: console + + systemd-udevd[4848]: renamed network interface eth0 to ens5f0 + systemd-udevd[4848]: renamed network interface eth1 to ens5f1 + +#. Bring up the PF ports: + + .. code-block:: console + + ifconfig ens5f0 up + ifconfig ens5f1 up + +#. Create VF device(s): + + .. code-block:: console + + Echo the number of VFs to be created into "sriov_numvfs" sysfs entry + of the parent PF. + + Example output: + + .. code-block:: console + + echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs + + +#. Assign VF MAC address: + + .. code-block:: console + + Assign MAC address to the VF using iproute2 ulility. The syntax is: + ip link set vf mac + + Example output: + + .. code-block:: console + + ip link set ens5f0 vf 0 mac 52:54:00:2f:9d:e8 + + +#. PCI passthrough: + + .. code-block:: console + + The VF devices may be passthru'ed to the guest VM using virt-manager or virsh etc. + bnx2x PMD should be used to bind the VF devices in the guest VM using the instructions + outlined in Application notes. + + +FreeBSD +------- + +.. _freebsd-installation: + +FreeBSD Installation +~~~~~~~~~~~~~~~~~~~~ + +Sample Application Notes +~~~~~~~~~~~~~~~~~~~~~~~~ -- 1.7.10.3