On Mon, Apr 19, 2021 at 8:46 PM Kalesh A P wrote: > > From: Kalesh AP > > Driver cancels the health check alarm only if error recovery is enabled > in the FW. This can cause an issue. There is a small window where the > driver receives the async event from fw and port close is invoked > immediately. Driver clears BNXT_FLAG_RECOVERY_ENABLED flag when it gets > the async event from FW. As a result, the health check alarm will not > get canceled during port close and causes a segfault when the alarm tries > to read Heartbeat register. > > Fix this by cancelling the health check alarm unconditionally during > port stop. > > Fixes: 9d0cbaecc91a ("net/bnxt: support periodic FW health monitoring") > Cc: stable@dpdk.org > > Signed-off-by: Kalesh AP > Reviewed-by: Somnath Kotur > Reviewed-by: Ajit Kumar Khaparde Patch applied to dpdk-next-net-brcm. > --- > drivers/net/bnxt/bnxt_ethdev.c | 3 --- > 1 file changed, 3 deletions(-) > > diff --git a/drivers/net/bnxt/bnxt_ethdev.c b/drivers/net/bnxt/bnxt_ethdev.c > index 9da817f..f5d2dc8 100644 > --- a/drivers/net/bnxt/bnxt_ethdev.c > +++ b/drivers/net/bnxt/bnxt_ethdev.c > @@ -4274,9 +4274,6 @@ void bnxt_schedule_fw_health_check(struct bnxt *bp) > > static void bnxt_cancel_fw_health_check(struct bnxt *bp) > { > - if (!bnxt_is_recovery_enabled(bp)) > - return; > - > rte_eal_alarm_cancel(bnxt_check_fw_health, (void *)bp); > bp->flags &= ~BNXT_FLAG_FW_HEALTH_CHECK_SCHEDULED; > } > -- > 2.10.1 >