From mboxrd@z Thu Jan 1 00:00:00 1970
Return-Path:
Received: from mails.dpdk.org (mails.dpdk.org [217.70.189.124])
by inbox.dpdk.org (Postfix) with ESMTP id 8E8AF46179;
Mon, 3 Feb 2025 03:54:08 +0100 (CET)
Received: from mails.dpdk.org (localhost [127.0.0.1])
by mails.dpdk.org (Postfix) with ESMTP id 6938A4060F;
Mon, 3 Feb 2025 03:54:08 +0100 (CET)
Received: from inbox.dpdk.org (inbox.dpdk.org [95.142.172.178])
by mails.dpdk.org (Postfix) with ESMTP id B0E7D400EF
for ; Mon, 3 Feb 2025 03:54:04 +0100 (CET)
Received: by inbox.dpdk.org (Postfix, from userid 33)
id 926254617B; Mon, 3 Feb 2025 03:54:04 +0100 (CET)
From: bugzilla@dpdk.org
To: dev@dpdk.org
Subject: [DPDK/core Bug 1634] Twinpond and Ironpond NICs do not report link
status correctly
Date: Mon, 03 Feb 2025 02:54:04 +0000
X-Bugzilla-Reason: AssignedTo
X-Bugzilla-Type: new
X-Bugzilla-Watch-Reason: None
X-Bugzilla-Product: DPDK
X-Bugzilla-Component: core
X-Bugzilla-Version: unspecified
X-Bugzilla-Keywords:
X-Bugzilla-Severity: normal
X-Bugzilla-Who: nandinipersad361@gmail.com
X-Bugzilla-Status: UNCONFIRMED
X-Bugzilla-Resolution:
X-Bugzilla-Priority: Normal
X-Bugzilla-Assigned-To: dev@dpdk.org
X-Bugzilla-Target-Milestone: ---
X-Bugzilla-Flags:
X-Bugzilla-Changed-Fields: bug_id short_desc product version rep_platform
op_sys bug_status bug_severity priority component assigned_to reporter
target_milestone
Message-ID:
Content-Type: multipart/alternative; boundary=17385512440.ffE52e16.2114389
Content-Transfer-Encoding: 7bit
X-Bugzilla-URL: http://bugs.dpdk.org/
Auto-Submitted: auto-generated
X-Auto-Response-Suppress: All
MIME-Version: 1.0
X-BeenThere: dev@dpdk.org
X-Mailman-Version: 2.1.29
Precedence: list
List-Id: DPDK patches and discussions
List-Unsubscribe: ,
List-Archive:
List-Post:
List-Help:
List-Subscribe: ,
Errors-To: dev-bounces@dpdk.org
--17385512440.ffE52e16.2114389
Date: Mon, 3 Feb 2025 03:54:04 +0100
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8
Content-Transfer-Encoding: quoted-printable
X-Bugzilla-URL: http://bugs.dpdk.org/
Auto-Submitted: auto-generated
X-Auto-Response-Suppress: All
https://bugs.dpdk.org/show_bug.cgi?id=3D1634
Bug ID: 1634
Summary: Twinpond and Ironpond NICs do not report link status
correctly
Product: DPDK
Version: unspecified
Hardware: All
OS: All
Status: UNCONFIRMED
Severity: normal
Priority: Normal
Component: core
Assignee: dev@dpdk.org
Reporter: nandinipersad361@gmail.com
Target Milestone: ---
Twin Pond/Iron Pond NICs do not bring the physical link down when shutting =
down
the port.
Implication:
The link is reported as up even after issuing shutdown command unless the c=
able
is physically disconnected.
Resolution/Workaround:
None.
Affected Environment/Platform:
Twin Pond and Iron Pond NICs
Driver/Module:
Poll Mode Driver (PMD).
--=20
You are receiving this mail because:
You are the assignee for the bug.=
--17385512440.ffE52e16.2114389
Date: Mon, 3 Feb 2025 03:54:04 +0100
MIME-Version: 1.0
Content-Type: text/html; charset=UTF-8
Content-Transfer-Encoding: quoted-printable
X-Bugzilla-URL: http://bugs.dpdk.org/
Auto-Submitted: auto-generated
X-Auto-Response-Suppress: All
Twinpond and Ironpond NICs do not report link status correctly
Product
DPDK
Version
unspecified
Hardware
All
OS
All
Status
UNCONFIRMED
Severity
normal
Priority
Normal
Component
core
Assignee
dev@dpdk.org
Reporter
nandinipersad361@gmail.com
Target Milestone
---
Twin Pond/Iron Pond NICs do not br=
ing the physical link down when shutting down
the port.
Implication:
The link is reported as up even after issuing shutdown command unless the c=
able
is physically disconnected.
Resolution/Workaround:
None.
Affected Environment/Platform:
Twin Pond and Iron Pond NICs
Driver/Module:
Poll Mode Driver (PMD).