* [dpdk-dev] [PATCH] net/enic: fix segfault caused by changing MTU
@ 2021-10-26 0:02 Hyong Youb Kim
2021-11-03 18:41 ` Ferruh Yigit
0 siblings, 1 reply; 2+ messages in thread
From: Hyong Youb Kim @ 2021-10-26 0:02 UTC (permalink / raw)
To: Ferruh Yigit; +Cc: dev, Hyong Youb Kim, John Daley
Changing MTU after the device start causes a segfault in the Rx
handler. The MTU handler (enic_set_mtu) performs the following steps.
1. Stop NIC Rx
2. Change Rx handler '(struct rte_eth_dev)->rx_pkt_burst' to
the dummy handler and sleep a while to quiesce
3. Re-allocate/initialize Rx structures
4. Change Rx handler back to the real handler
(e.g. enic_noscatter_recv_pkts)
enic_set_mtu does not update the recently introduced fast-path pointer
'(struct rte_eth_fp_ops)->rx_pkt_burst'. Since rte_eth_rx_burst only
uses the fast-path pointer, it keeps invoking the real Rx handler, not
the dummy one set by (2). And, (3) causes a segfault in the real Rx
handler (e.g. dereferencing freed structures).
Fix the segfault by updating the fast-path pointer as well.
Fixes: c87d435a4d79 ("ethdev: copy fast-path API into separate structure")
Signed-off-by: Hyong Youb Kim <hyonkim@cisco.com>
Reviewed-by: John Daley <johndale@cisco.com>
---
drivers/net/enic/enic_main.c | 2 ++
1 file changed, 2 insertions(+)
diff --git a/drivers/net/enic/enic_main.c b/drivers/net/enic/enic_main.c
index 21b1fffb14..42bf363529 100644
--- a/drivers/net/enic/enic_main.c
+++ b/drivers/net/enic/enic_main.c
@@ -1665,6 +1665,7 @@ int enic_set_mtu(struct enic *enic, uint16_t new_mtu)
/* replace Rx function with a no-op to avoid getting stale pkts */
eth_dev->rx_pkt_burst = enic_dummy_recv_pkts;
+ rte_eth_fp_ops[enic->port_id].rx_pkt_burst = eth_dev->rx_pkt_burst;
rte_mb();
/* Allow time for threads to exit the real Rx function. */
@@ -1699,6 +1700,7 @@ int enic_set_mtu(struct enic *enic, uint16_t new_mtu)
/* put back the real receive function */
rte_mb();
enic_pick_rx_handler(eth_dev);
+ rte_eth_fp_ops[enic->port_id].rx_pkt_burst = eth_dev->rx_pkt_burst;
rte_mb();
/* restart Rx traffic */
--
2.26.2
^ permalink raw reply [flat|nested] 2+ messages in thread
* Re: [dpdk-dev] [PATCH] net/enic: fix segfault caused by changing MTU
2021-10-26 0:02 [dpdk-dev] [PATCH] net/enic: fix segfault caused by changing MTU Hyong Youb Kim
@ 2021-11-03 18:41 ` Ferruh Yigit
0 siblings, 0 replies; 2+ messages in thread
From: Ferruh Yigit @ 2021-11-03 18:41 UTC (permalink / raw)
To: Hyong Youb Kim; +Cc: dev, John Daley
On 10/26/2021 1:02 AM, Hyong Youb Kim wrote:
> Changing MTU after the device start causes a segfault in the Rx
> handler. The MTU handler (enic_set_mtu) performs the following steps.
> 1. Stop NIC Rx
> 2. Change Rx handler '(struct rte_eth_dev)->rx_pkt_burst' to
> the dummy handler and sleep a while to quiesce
> 3. Re-allocate/initialize Rx structures
> 4. Change Rx handler back to the real handler
> (e.g. enic_noscatter_recv_pkts)
>
> enic_set_mtu does not update the recently introduced fast-path pointer
> '(struct rte_eth_fp_ops)->rx_pkt_burst'. Since rte_eth_rx_burst only
> uses the fast-path pointer, it keeps invoking the real Rx handler, not
> the dummy one set by (2). And, (3) causes a segfault in the real Rx
> handler (e.g. dereferencing freed structures).
>
> Fix the segfault by updating the fast-path pointer as well.
>
> Fixes: c87d435a4d79 ("ethdev: copy fast-path API into separate structure")
>
> Signed-off-by: Hyong Youb Kim <hyonkim@cisco.com>
> Reviewed-by: John Daley <johndale@cisco.com>
Applied to dpdk-next-net/main, thanks.
^ permalink raw reply [flat|nested] 2+ messages in thread
end of thread, other threads:[~2021-11-03 18:42 UTC | newest]
Thread overview: 2+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2021-10-26 0:02 [dpdk-dev] [PATCH] net/enic: fix segfault caused by changing MTU Hyong Youb Kim
2021-11-03 18:41 ` Ferruh Yigit
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).