From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Received: from mga04.intel.com (mga04.intel.com [192.55.52.120]) by dpdk.org (Postfix) with ESMTP id B5C9DFA48 for ; Mon, 16 Jan 2017 04:17:43 +0100 (CET) Received: from orsmga001.jf.intel.com ([10.7.209.18]) by fmsmga104.fm.intel.com with ESMTP; 15 Jan 2017 19:17:42 -0800 X-ExtLoop1: 1 X-IronPort-AV: E=Sophos;i="5.33,237,1477983600"; d="scan'208";a="1083413253" Received: from unknown (HELO dpdk-fedora20.icx.intel.com) ([10.240.176.135]) by orsmga001.jf.intel.com with ESMTP; 15 Jan 2017 19:17:41 -0800 From: yufengmx To: dts@dpdk.org Cc: Peng Yuan Date: Mon, 16 Jan 2017 11:18:45 +0800 Message-Id: <1484536725-45668-1-git-send-email-yufengx.mo@intel.com> X-Mailer: git-send-email 1.9.3 Subject: [dts] [PATCH] test_plans: modify the format of floating veb test plan X-BeenThere: dts@dpdk.org X-Mailman-Version: 2.1.15 Precedence: list List-Id: test suite reviews and discussions List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , X-List-Received-Date: Mon, 16 Jan 2017 03:17:44 -0000 From: Peng Yuan Signed-off-by: Peng Yuan diff --git a/test_plans/floating_veb_test_plan.rst b/test_plans/floating_veb_test_plan.rst new file mode 100644 index 0000000..244fed9 --- /dev/null +++ b/test_plans/floating_veb_test_plan.rst @@ -0,0 +1,407 @@ +.. Copyright (c) <2016>, Intel Corporation + All rights reserved. + + Redistribution and use in source and binary forms, with or without + modification, are permitted provided that the following conditions + are met: + + - Redistributions of source code must retain the above copyright + notice, this list of conditions and the following disclaimer. + + - Redistributions in binary form must reproduce the above copyright + notice, this list of conditions and the following disclaimer in + the documentation and/or other materials provided with the + distribution. + + - Neither the name of Intel Corporation nor the names of its + contributors may be used to endorse or promote products derived + from this software without specific prior written permission. + + THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS + "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT + LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS + FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE + COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, + INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES + (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR + SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) + HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, + STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) + ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED + OF THE POSSIBILITY OF SUCH DAMAGE. + +===================================== +VEB Switch and floating VEB Test Plan +===================================== + +VEB Switching Introduction +========================== + +IEEE EVB tutorial: +http://www.ieee802.org/802_tutorials/2009-11 +/evb-tutorial-draft-20091116_v09.pdf + +Virtual Ethernet Bridge (VEB) - This is an IEEE EVB term. A VEB is a VLAN +Bridge internal to Fortville that bridges the traffic of multiple VSIs over + an internal virtual network. + +Virtual Ethernet Port Aggregator (VEPA) - This is an IEEE EVB term. A VEPA +multiplexes the traffic of one or more VSIs onto a single Fortville Ethernet +port. The biggest difference between a VEB and a VEPA is that a VEB can +switch packets internally between VSIs, whereas a VEPA cannot. + +Virtual Station Interface (VSI) - This is an IEEE EVB term that defines +the properties of a virtual machine's (or a physical machine's) connection +to the network. Each downstream v-port on a Fortville VEB or VEPA defines +a VSI. A standards-based definition of VSI properties enables network +management tools to perform virtual machine migration and associated network +re-configuration in a vendor-neutral manner. + +My understanding of VEB is that it's an in-NIC switch(MAC/VLAN), and it can +support VF->VF, PF->VF, VF->PF packet forwarding according to the NIC internal +switch. It's similar as Niantic's SRIOV switch. + +Floating VEB Introduction +========================= + +Floating VEB is based on VEB Switching. It will address 2 problems: + +Dependency on PF: When the physical port is link down, the functionality of +the VEB/VEPA will not work normally. Even only data forwarding between the VF +is required, one PF port will be wasted to create the related VEB. + +Ensure all the traffic from VF can only forwarding within the VFs connect +to the floating VEB, cannot forward to the outside world. + +Prerequisites for VEB testing +============================= + +1. Get the pci device id of DUT, for example:: + + ./dpdk-devbind.py --st + 0000:05:00.0 'Ethernet Controller X710 for 10GbE SFP+' if=ens785f0 drv=i40e + unused= + +2.1 Host PF in kernel driver. Create 2 VFs from 1 PF with kernel driver, + and set the VF MAC address at PF:: + + echo 2 > /sys/bus/pci/devices/0000\:05\:00.0/sriov_numvfs + ./dpdk-devbind.py --st + + 0000:05:02.0 'XL710/X710 Virtual Function' unused= + 0000:05:02.1 'XL710/X710 Virtual Function' unused= + + ip link set ens785f0 vf 0 mac 00:11:22:33:44:11 + ip link set ens785f0 vf 1 mac 00:11:22:33:44:12 + +2.2 Host PF in DPDK driver. Create 2VFs from 1 PF with dpdk driver:: + + ./dpdk-devbind.py -b igb_uio 05:00.0 + echo 2 >/sys/bus/pci/devices/0000:05:00.0/max_vfs + ./dpdk-devbind.py --st + 0000:05:02.0 'XL710/X710 Virtual Function' unused=i40evf,igb_uio + 0000:05:02.1 'XL710/X710 Virtual Function' unused=i40evf,igb_uio + +3. Bind the VFs to dpdk driver:: + + ./tools/dpdk-devbind.py -b igb_uio 05:02.0 05:02.1 + +4. Reserve huge pages memory(before using DPDK):: + + echo 4096 > /sys/devices/system/node/node0/hugepages/hugepages-2048kB + /nr_hugepages + mkdir /mnt/huge + mount -t hugetlbfs nodev /mnt/huge + + +Test Case1: Floating VEB inter VF-VF +==================================== + +Summary: 1 DPDK PF, then create 2VF, PF in the host running dpdk testpmd, +and VF0 are running dpdk testpmd, VF0 send traffic, and set the packet's +DEST MAC to VF1, check if VF1 can receive the packets. Check Inter VF-VF +MAC switch when PF is link down as well as up. + +Launch PF testpmd:: + ./testpmd -c 0xf -n 4 --socket-mem 1024,1024 + -w 05:00.0,enable_floating_veb=1 --file-prefix=test1 -- -i + +2. In the host, run testpmd with floating parameters and make the link down:: + + ./testpmd -c 0xf -n 4 --socket-mem 1024,1024 + -w 05:00.0,enable_floating_veb=1 --file-prefix=test1 -- -i + testpmd> port start all + testpmd> show port info all + +3. In VM1, run testpmd:: + + ./testpmd -c 0xf0 -n 4 --socket-mem 1024,1024 + -w 05:02.0 --file-prefix=test2 -- -i --crc-strip + testpmd>mac_addr add 0 vf1_mac_address + testpmd>set fwd rxonly + testpmd>start + testpmd>show port stats all + + In VM2, run testpmd:: + + ./testpmd -c 0xf00 -n 4 --socket-mem 1024,1024 -w 05:02.1 --file-prefix=test3 + -- -i --crc-strip --eth-peer=0,vf1_mac_address + testpmd>set fwd txonly + testpmd>start + testpmd>show port stats all + +4. check if VF1 can get all the packets. Check the packet content is no + corrupted. RX-packets=TX-packets, but there is a little RX-error. + RF receive no packets. + +5. Set "testpmd> port stop all" and "testpmd> start" in step2, + then run the step3-4 again. same result. + + +Test Case2: Floating VEB PF can't get traffic from VF +===================================================== +DPDK PF, then create 1VF, PF in the host running dpdk testpmd, +send traffic from PF to VF0, VF0 can't receive any packets; +send traffic from VF0 to PF, PF can't receive any packets either. + + +1. In host, launch testpmd:: + + ./testpmd -c 0x3 -n 4 -w 82:00.0,enable_floating_veb=1 -- -i + testpmd> set fwd rxonly + testpmd> port start all + testpmd> start + testpmd> show port stats all + +3. In VM1, run testpmd:: + + ./testpmd -c 0x3 -n 4 -- -i --eth-peer=0,pf_mac_addr + testpmd>set fwd txonly + testpmd>start + testpmd>show port stats all + +4. Check if PF can not get any packets, so VF1->PF is not working. + +5. Set "testpmd> port stop all" in step2, then run the test case again. + Same result. + + + +Test Case3 Floating VEB VF can't receive traffic from outside world +=================================================================== + +DPDK PF, then create 1VF, send traffic from tester to VF1, +in floating mode, check VF1 can't receive traffic from tester. + +1. Start VM1 with VF1, see the prerequisite part. + +2. In host, launch testpmd:: + + ./testpmd -c 0x3 -n 4 -w 82:00.0,enable_floating_veb=1 -- -i + testpmd> set fwd mac + testpmd> port start all + testpmd> start + testpmd> show port stats all + + + In VM1, run testpmd: + + ./testpmd -c 0x3 -n 4 -- -i + testpmd>show port info all //get VF_mac_address + testpmd>set fwd rxonly + testpmd>start + testpmd>show port stats all + + In tester, run scapy + + packet=Ether(dst="VF_mac_address")/IP()/UDP()/Raw('x'*20) + sendp(packet,iface="enp132s0f0") + +3. Check if VF1 can not get any packets, so tester->VF1 is not working. +4. Set "testpmd> port stop all" in step2 in Host, then run the test case + again. same result.PF can't receive any packets. + + +Test Case4: Floating VEB VF can not communicate with legacy VEB VF +================================================================== + +Summary: DPDK PF, then create 4VFs and 4VMs, VF1,VF3,VF4, floating VEB; +VF2, lagecy VEB. Make PF link down(the cable can be pluged out), +VFs in VMs are running dpdk testpmd. +1. VF1 send traffic, and set the packet's DEST MAC to VF2, + check VF2 can not receive the packets. +2. VF1 send traffic, and set the packet's DEST MAC to VF3, + check VF3 can receive the packets. +3. VF4 send traffic, and set the packet's DEST MAC to VF3, + check VF3 can receive the packets. +4. VF2 send traffic, and set the packet's DEST MAC to VF1, + check VF1 can not receive the packets. +Check Inter-VM VF-VF MAC switch when PF is link down as well as up. + +Launch PF testpmd:: + ./testpmd -c 0x3 -n 4 + -w "82:00.0,enable_floating_veb=1,floating_veb_list=0;2-3" -- -i + +1. Start VM1 with VF1, VM2 with VF2, VM3 with VF3, + VM4 with VF4,see the prerequisite part. + +2. In the host, run testpmd with floating parameters and make the link down:: + + ./testpmd -c 0x3 -n 4 + -w "82:00.0,enable_floating_veb=1,floating_veb_list=0;2-3" -- -i + //VF1 and VF3 in floating VEB, VF2 in legacy VEB + + testpmd> port stop all + //this step should be executed after vf running testpmd. + + testpmd> show port info all + +3. VF1 send traffic, and set the packet's DEST MAC to VF2, + check VF2 can not receive the packets. + + In VM2, run testpmd:: + + ./testpmd -c 0x3 -n 4 -- -i + testpmd>set fwd rxonly + testpmd>mac_addr add 0 vf2_mac_address //set the vf2_mac_address + testpmd>start + testpmd>show port stats all + + In VM1, run testpmd:: + + ./testpmd -c 0x3 -n 4 -- -i --eth-peer=0,vf2_mac_address + testpmd>set fwd txonly + testpmd>start + testpmd>show port stats all + + Check VF2 can not get any packets, so VF1->VF2 is not working. + +4. VF1 send traffic, and set the packet's DEST MAC to VF3, + check VF3 can receive the packets. + + In VM3, run testpmd:: + + ./testpmd -c 0x3 -n 4 -- -i + testpmd>set fwd rxonly + testpmd>show port info all //get the vf3_mac_address + testpmd>start + testpmd>show port stats all + + In VM1, run testpmd:: + + ./testpmd -c 0x3 -n 4 -- -i --eth-peer=0,vf3_mac_address + testpmd>set fwd txonly + testpmd>start + testpmd>show port stats all + + Check VF3 can get all the packets. Check the packet content is no corrupted. + so VF1->VF2 is working. + +5. VF2 send traffic, and set the packet's DEST MAC to VF1, + check VF1 can not receive the packets. + + In VM1, run testpmd:: + + ./testpmd -c 0x3 -n 4 -- -i + testpmd>set fwd rxonly + testpmd>show port info all //get the vf1_mac_address + testpmd>start + testpmd>show port stats all + + In VM2, run testpmd:: + + ./testpmd -c 0x3 -n 4 -- -i --eth-peer=0,vf1_mac_address + testpmd>set fwd txonly + testpmd>start + testpmd>show port stats all + + Check VF1 can not get any packets, so VF2->VF1 is not working. + +6. Set "testpmd> port start all" and "testpmd> start" in step2, + then run the step3-5 again. same result. + + +Test Case5: PF interaction with Floating VF and legacy VF +========================================================= +DPDK PF, then create 2VFs, VF0 is in floating VEB, VF1 is in legacy VEB. +1. Send traffic from VF0 to PF, then check PF will not see any traffic; +2. Send traffic from VF1 to PF, then check PF will receive all the packets. +3. send traffic from tester to VF0, check VF0 can't receive traffic from + tester. +4. send traffic from tester to VF1, check VF1 can receive all the traffic + from tester. + +1. In host, launch testpmd:: + + ./testpmd -c 0x3 -n 4 + -w 82:00.0,enable_floating_veb=1,floating_veb_list=0 -- -i + testpmd> set fwd rxonly + testpmd> port start all + testpmd> start + testpmd> show port stats all + +3. In VF1, run testpmd:: + + ./testpmd -c 0x3 -n 4 -- -i --eth-peer=0,pf_mac_addr + testpmd>set fwd txonly + testpmd>start + testpmd>show port stats all + + Check PF can not get any packets, so VF1->PF is not working. + +4. In VF2, run testpmd:: + + ./testpmd -c 0x3 -n 4 -- -i --eth-peer=0,pf_mac_addr + testpmd>set fwd txonly + testpmd>start + testpmd>show port stats all + + Check PF can get all the packets, so VF2->PF is working. + +5. Set "testpmd> port stop all" in step2 in Host, + then run the test case again. same result. + +6. In host, launch testpmd:: + + ./testpmd -c 0x3 -n 4 + -w 82:00.0,enable_floating_veb=1,floating_veb_list=0 -- -i + testpmd> set fwd mac + testpmd> port start all + testpmd> start + testpmd> show port stats all + + +7. In VF1, run testpmd:: + + ./testpmd -c 0x3 -n 4 -- -i + testpmd>show port info all //get VF1_mac_address + testpmd>set fwd rxonly + testpmd>start + testpmd>show port stats all + + In tester, run scapy + + packet=Ether(dst="VF1_mac_address")/IP()/UDP()/Raw('x'*20) + sendp(packet,iface="enp132s0f0") + + Check VF1 can not get any packets, so tester->VF1 is not working. + +8. In VF2, run testpmd:: + + ./testpmd -c 0x3 -n 4 -- -i + testpmd>show port info all //get VF2_mac_address + testpmd>set fwd rxonly + testpmd>start + testpmd>show port stats all + + In tester, run scapy + + packet=Ether(dst="VF2_mac_address")/IP()/UDP()/Raw('x'*20) + sendp(packet,iface="enp132s0f0") + + Check VF1 can get all the packets, so tester->VF2 is working. + +5. Set "testpmd> port stop all" in step2 in Host, then run the test case again. + VF1 and VF2 cannot receive any packets. (because PF link down, + and PF can't receive any packets. so even if VF2 can't receive any packets.) + -- 2.5.0