test suite reviews and discussions
 help / color / mirror / Atom feed
From: Yinan <yinan.wang@intel.com>
To: dts@dpdk.org
Cc: Wang Yinan <yinan.wang@intel.com>
Subject: [dts] [PATCH v1] test_plans: add per-patch performance test fpr vm2vm_virtio_net
Date: Tue,  3 Mar 2020 22:28:41 +0000	[thread overview]
Message-ID: <20200303222841.4550-1-yinan.wang@intel.com> (raw)

From: Wang Yinan <yinan.wang@intel.com>

Signed-off-by: Wang Yinan <yinan.wang@intel.com>
---
 .../perf_vm2vm_virtio_net_perf_test_plan.rst  | 245 ++++++++++++++++++
 1 file changed, 245 insertions(+)
 create mode 100644 test_plans/perf_vm2vm_virtio_net_perf_test_plan.rst

diff --git a/test_plans/perf_vm2vm_virtio_net_perf_test_plan.rst b/test_plans/perf_vm2vm_virtio_net_perf_test_plan.rst
new file mode 100644
index 0000000..608703a
--- /dev/null
+++ b/test_plans/perf_vm2vm_virtio_net_perf_test_plan.rst
@@ -0,0 +1,245 @@
+.. Copyright (c) <2019>, Intel Corporation
+   All rights reserved.
+
+   Redistribution and use in source and binary forms, with or without
+   modification, are permitted provided that the following conditions
+   are met:
+
+   - Redistributions of source code must retain the above copyright
+     notice, this list of conditions and the following disclaimer.
+
+   - Redistributions in binary forim must reproduce the above copyright
+     notice, this list of conditions and the following disclaimer in
+     the documentation and/or other materials provided with the
+     distribution.
+
+   - Neither the name of Intel Corporation nor the names of its
+     contributors may be used to endorse or promote products derived
+     from this software without specific prior written permission.
+
+   THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
+   "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
+   LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
+   FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
+   COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
+   INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
+   (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
+   SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
+   HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
+   STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
+   ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED
+   OF THE POSSIBILITY OF SUCH DAMAGE.
+
+==========================================
+perf vm2vm vhost-user/virtio-net test plan
+==========================================
+
+Description
+===========
+
+This test plan test vhost tx offload (TSO) function by verifing the TSO/cksum in the TCP/IP stack enabled environment with vm2vm split ring and packed ring vhost-user/virtio-net non-mergeable path. For packed virtqueue virtio-net test, need qemu version > 4.2.0 and VM kernel version > v5.1.
+
+Test flow
+=========
+
+Virtio-net <-> Vhost <-> Testpmd <-> Vhost <-> Virtio-net
+
+Test Case 1: Perf VM2VM split ring vhost-user/virtio-net test with tcp traffic
+==============================================================================
+
+1. Launch the Vhost sample by below commands::
+
+    rm -rf vhost-net*
+    ./testpmd -l 2-4 -n 4 --socket-mem 2048,2048 --legacy-mem --no-pci --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net0,queues=1' --vdev 'net_vhost1,iface=vhost-net1,queues=1'  -- -i --nb-cores=2 --txd=1024 --rxd=1024
+    testpmd>start
+
+2. Launch VM1 and VM2::
+
+    qemu-system-x86_64 -name us-vhost-vm1 \
+     -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \
+     -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-1.img  \
+     -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6004-:22 \
+     -chardev socket,id=char0,path=./vhost-net0 -netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce \
+     -device virtio-net-pci,mac=52:54:00:00:00:01,netdev=mynet1,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on \
+     -vnc :12 -daemonize
+
+    qemu-system-x86_64 -name us-vhost-vm2 \
+     -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \
+     -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-2.img \
+     -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6005-:22 \
+     -chardev socket,id=char1,path=./vhost-net1 -netdev type=vhost-user,id=mynet2,chardev=char1,vhostforce \
+     -device virtio-net-pci,mac=52:54:00:00:00:02,netdev=mynet2,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on \
+     -vnc :11 -daemonize
+
+3. On VM1, set virtio device IP and run arp protocal::
+
+    ifconfig ens3 1.1.1.2
+    arp -s 1.1.1.8 52:54:00:00:00:02
+
+4. On VM2, set virtio device IP and run arp protocal::
+
+    ifconfig ens3 1.1.1.8
+    arp -s 1.1.1.2 52:54:00:00:00:01
+
+5. Check the iperf performance between two VMs by below commands::
+
+    Under VM1, run: `iperf -s -i 1`
+    Under VM2, run: `iperf -c 1.1.1.2 -i 1 -t 30`
+
+6. Check both 2VMs can receive and send big packets to each other::
+
+    testpmd>show port xstats all
+    Port 0 should have tx packets above 1522
+    Port 1 should have rx packets above 1522
+
+7. Check iperf throughput can get expected data.
+
+Test Case 2: Perf VM2VM split ring vhost-user/virtio-net dequeue zero-copy test with tcp traffic
+================================================================================================
+
+1. Launch the Vhost sample by below commands::
+
+    rm -rf vhost-net*
+    ./testpmd -l 2-4 -n 4 --socket-mem 2048,2048 --legacy-mem --no-pci --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net0,queues=1,dequeue-zero-copy=1' --vdev 'net_vhost1,iface=vhost-net1,queues=1,dequeue-zero-copy=1'  -- -i --nb-cores=2 --txd=1024 --rxd=1024
+    testpmd>start
+
+2. Launch VM1 and VM2::
+
+    qemu-system-x86_64 -name us-vhost-vm1 \
+     -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \
+     -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-1.img  \
+     -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6004-:22 \
+     -chardev socket,id=char0,path=./vhost-net0 -netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce \
+     -device virtio-net-pci,mac=52:54:00:00:00:01,netdev=mynet1,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on \
+     -vnc :12 -daemonize
+
+    qemu-system-x86_64 -name us-vhost-vm2 \
+     -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \
+     -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-2.img \
+     -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6005-:22 \
+     -chardev socket,id=char1,path=./vhost-net1 -netdev type=vhost-user,id=mynet2,chardev=char1,vhostforce \
+     -device virtio-net-pci,mac=52:54:00:00:00:02,netdev=mynet2,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on \
+     -vnc :11 -daemonize
+
+3. On VM1, set virtio device IP and run arp protocal::
+
+    ifconfig ens3 1.1.1.2
+    arp -s 1.1.1.8 52:54:00:00:00:02
+
+4. On VM2, set virtio device IP and run arp protocal::
+
+    ifconfig ens3 1.1.1.8
+    arp -s 1.1.1.2 52:54:00:00:00:01
+
+5. Check the iperf performance between two VMs by below commands::
+
+    Under VM1, run: `iperf -s -i 1`
+    Under VM2, run: `iperf -c 1.1.1.2 -i 1 -t 30`
+
+6. Check both 2VMs can receive and send big packets to each other::
+
+    testpmd>show port xstats all
+    Port 0 should have tx packets above 1522
+    Port 1 should have rx packets above 1522
+
+7. Check iperf throughput can get expected data.
+
+Test Case 3: Perf VM2VM packed ring vhost-user/virtio-net test with tcp traffic
+===============================================================================
+
+1. Launch the Vhost sample by below commands::
+
+    rm -rf vhost-net*
+    ./testpmd -l 2-4 -n 4 --socket-mem 2048,2048 --legacy-mem --no-pci --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net0,queues=1' --vdev 'net_vhost1,iface=vhost-net1,queues=1'  -- -i --nb-cores=2 --txd=1024 --rxd=1024
+    testpmd>start
+
+2. Launch VM1 and VM2::
+
+    qemu-system-x86_64 -name us-vhost-vm1 \
+     -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \
+     -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-1.img  \
+     -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6004-:22 \
+     -chardev socket,id=char0,path=./vhost-net0 -netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce \
+     -device virtio-net-pci,mac=52:54:00:00:00:01,netdev=mynet1,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,packed=on \
+     -vnc :12 -daemonize
+
+    qemu-system-x86_64 -name us-vhost-vm2 \
+     -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \
+     -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-2.img \
+     -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6005-:22 \
+     -chardev socket,id=char1,path=./vhost-net1 -netdev type=vhost-user,id=mynet2,chardev=char1,vhostforce \
+     -device virtio-net-pci,mac=52:54:00:00:00:02,netdev=mynet2,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,packed=on \
+     -vnc :11 -daemonize
+
+3. On VM1, set virtio device IP and run arp protocal::
+
+    ifconfig ens3 1.1.1.2
+    arp -s 1.1.1.8 52:54:00:00:00:02
+
+4. On VM2, set virtio device IP and run arp protocal::
+
+    ifconfig ens3 1.1.1.8
+    arp -s 1.1.1.2 52:54:00:00:00:01
+
+5. Check the iperf performance between two VMs by below commands::
+
+    Under VM1, run: `iperf -s -i 1`
+    Under VM2, run: `iperf -c 1.1.1.2 -i 1 -t 30`
+
+6. Check both 2VMs can receive and send big packets to each other::
+
+    testpmd>show port xstats all
+    Port 0 should have tx packets above 1522
+    Port 1 should have rx packets above 1522
+
+7. Check iperf throughput can get expected data.
+
+Test Case 4: Perf VM2VM packed ring vhost-user/virtio-net dequeue zero-copy test with tcp traffic
+=================================================================================================
+
+1. Launch the Vhost sample by below commands::
+
+    rm -rf vhost-net*
+    ./testpmd -l 2-4 -n 4 --socket-mem 2048,2048 --legacy-mem --no-pci --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net0,queues=1,dequeue-zero-copy=1' --vdev 'net_vhost1,iface=vhost-net1,queues=1,dequeue-zero-copy=1'  -- -i --nb-cores=2 --txd=1024 --rxd=1024
+    testpmd>start
+
+2. Launch VM1 and VM2::
+
+    qemu-system-x86_64 -name us-vhost-vm1 \
+     -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \
+     -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-1.img  \
+     -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6004-:22 \
+     -chardev socket,id=char0,path=./vhost-net0 -netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce \
+     -device virtio-net-pci,mac=52:54:00:00:00:01,netdev=mynet1,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,packed=on \
+     -vnc :12 -daemonize
+
+    qemu-system-x86_64 -name us-vhost-vm2 \
+     -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \
+     -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-2.img \
+     -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6005-:22 \
+     -chardev socket,id=char1,path=./vhost-net1 -netdev type=vhost-user,id=mynet2,chardev=char1,vhostforce \
+     -device virtio-net-pci,mac=52:54:00:00:00:02,netdev=mynet2,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,packed=on \
+     -vnc :11 -daemonize
+
+3. On VM1, set virtio device IP and run arp protocal::
+
+    ifconfig ens3 1.1.1.2
+    arp -s 1.1.1.8 52:54:00:00:00:02
+
+4. On VM2, set virtio device IP and run arp protocal::
+
+    ifconfig ens3 1.1.1.8
+    arp -s 1.1.1.2 52:54:00:00:00:01
+
+5. Check the iperf performance between two VMs by below commands::
+
+    Under VM1, run: `iperf -s -i 1`
+    Under VM2, run: `iperf -c 1.1.1.2 -i 1 -t 30`
+
+6. Check both 2VMs can receive and send big packets to each other::
+
+    testpmd>show port xstats all
+    Port 0 should have tx packets above 1522
+    Port 1 should have rx packets above 1522
+
+7. Check iperf throughput can get expected data.
\ No newline at end of file
-- 
2.17.1


                 reply	other threads:[~2020-03-04  5:34 UTC|newest]

Thread overview: [no followups] expand[flat|nested]  mbox.gz  Atom feed

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20200303222841.4550-1-yinan.wang@intel.com \
    --to=yinan.wang@intel.com \
    --cc=dts@dpdk.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).