From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Received: from dpdk.org (dpdk.org [92.243.14.124]) by inbox.dpdk.org (Postfix) with ESMTP id 99F64A056B; Wed, 4 Mar 2020 06:34:16 +0100 (CET) Received: from [92.243.14.124] (localhost [127.0.0.1]) by dpdk.org (Postfix) with ESMTP id 52DBF2C16; Wed, 4 Mar 2020 06:34:16 +0100 (CET) Received: from mga03.intel.com (mga03.intel.com [134.134.136.65]) by dpdk.org (Postfix) with ESMTP id B11E72BB8 for ; Wed, 4 Mar 2020 06:34:14 +0100 (CET) X-Amp-Result: SKIPPED(no attachment in message) X-Amp-File-Uploaded: False Received: from fmsmga004.fm.intel.com ([10.253.24.48]) by orsmga103.jf.intel.com with ESMTP/TLS/DHE-RSA-AES256-GCM-SHA384; 03 Mar 2020 21:34:13 -0800 X-ExtLoop1: 1 X-IronPort-AV: E=Sophos;i="5.70,513,1574150400"; d="scan'208";a="263473689" Received: from dpdk-yinan-purley.sh.intel.com ([10.67.117.227]) by fmsmga004.fm.intel.com with ESMTP; 03 Mar 2020 21:34:11 -0800 From: Yinan To: dts@dpdk.org Cc: Wang Yinan Date: Tue, 3 Mar 2020 22:28:41 +0000 Message-Id: <20200303222841.4550-1-yinan.wang@intel.com> X-Mailer: git-send-email 2.17.1 Subject: [dts] [PATCH v1] test_plans: add per-patch performance test fpr vm2vm_virtio_net X-BeenThere: dts@dpdk.org X-Mailman-Version: 2.1.15 Precedence: list List-Id: test suite reviews and discussions List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , Errors-To: dts-bounces@dpdk.org Sender: "dts" From: Wang Yinan Signed-off-by: Wang Yinan --- .../perf_vm2vm_virtio_net_perf_test_plan.rst | 245 ++++++++++++++++++ 1 file changed, 245 insertions(+) create mode 100644 test_plans/perf_vm2vm_virtio_net_perf_test_plan.rst diff --git a/test_plans/perf_vm2vm_virtio_net_perf_test_plan.rst b/test_plans/perf_vm2vm_virtio_net_perf_test_plan.rst new file mode 100644 index 0000000..608703a --- /dev/null +++ b/test_plans/perf_vm2vm_virtio_net_perf_test_plan.rst @@ -0,0 +1,245 @@ +.. Copyright (c) <2019>, Intel Corporation + All rights reserved. + + Redistribution and use in source and binary forms, with or without + modification, are permitted provided that the following conditions + are met: + + - Redistributions of source code must retain the above copyright + notice, this list of conditions and the following disclaimer. + + - Redistributions in binary forim must reproduce the above copyright + notice, this list of conditions and the following disclaimer in + the documentation and/or other materials provided with the + distribution. + + - Neither the name of Intel Corporation nor the names of its + contributors may be used to endorse or promote products derived + from this software without specific prior written permission. + + THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS + "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT + LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS + FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE + COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, + INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES + (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR + SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) + HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, + STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) + ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED + OF THE POSSIBILITY OF SUCH DAMAGE. + +========================================== +perf vm2vm vhost-user/virtio-net test plan +========================================== + +Description +=========== + +This test plan test vhost tx offload (TSO) function by verifing the TSO/cksum in the TCP/IP stack enabled environment with vm2vm split ring and packed ring vhost-user/virtio-net non-mergeable path. For packed virtqueue virtio-net test, need qemu version > 4.2.0 and VM kernel version > v5.1. + +Test flow +========= + +Virtio-net <-> Vhost <-> Testpmd <-> Vhost <-> Virtio-net + +Test Case 1: Perf VM2VM split ring vhost-user/virtio-net test with tcp traffic +============================================================================== + +1. Launch the Vhost sample by below commands:: + + rm -rf vhost-net* + ./testpmd -l 2-4 -n 4 --socket-mem 2048,2048 --legacy-mem --no-pci --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net0,queues=1' --vdev 'net_vhost1,iface=vhost-net1,queues=1' -- -i --nb-cores=2 --txd=1024 --rxd=1024 + testpmd>start + +2. Launch VM1 and VM2:: + + qemu-system-x86_64 -name us-vhost-vm1 \ + -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \ + -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-1.img \ + -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6004-:22 \ + -chardev socket,id=char0,path=./vhost-net0 -netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce \ + -device virtio-net-pci,mac=52:54:00:00:00:01,netdev=mynet1,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on \ + -vnc :12 -daemonize + + qemu-system-x86_64 -name us-vhost-vm2 \ + -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \ + -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-2.img \ + -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6005-:22 \ + -chardev socket,id=char1,path=./vhost-net1 -netdev type=vhost-user,id=mynet2,chardev=char1,vhostforce \ + -device virtio-net-pci,mac=52:54:00:00:00:02,netdev=mynet2,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on \ + -vnc :11 -daemonize + +3. On VM1, set virtio device IP and run arp protocal:: + + ifconfig ens3 1.1.1.2 + arp -s 1.1.1.8 52:54:00:00:00:02 + +4. On VM2, set virtio device IP and run arp protocal:: + + ifconfig ens3 1.1.1.8 + arp -s 1.1.1.2 52:54:00:00:00:01 + +5. Check the iperf performance between two VMs by below commands:: + + Under VM1, run: `iperf -s -i 1` + Under VM2, run: `iperf -c 1.1.1.2 -i 1 -t 30` + +6. Check both 2VMs can receive and send big packets to each other:: + + testpmd>show port xstats all + Port 0 should have tx packets above 1522 + Port 1 should have rx packets above 1522 + +7. Check iperf throughput can get expected data. + +Test Case 2: Perf VM2VM split ring vhost-user/virtio-net dequeue zero-copy test with tcp traffic +================================================================================================ + +1. Launch the Vhost sample by below commands:: + + rm -rf vhost-net* + ./testpmd -l 2-4 -n 4 --socket-mem 2048,2048 --legacy-mem --no-pci --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net0,queues=1,dequeue-zero-copy=1' --vdev 'net_vhost1,iface=vhost-net1,queues=1,dequeue-zero-copy=1' -- -i --nb-cores=2 --txd=1024 --rxd=1024 + testpmd>start + +2. Launch VM1 and VM2:: + + qemu-system-x86_64 -name us-vhost-vm1 \ + -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \ + -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-1.img \ + -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6004-:22 \ + -chardev socket,id=char0,path=./vhost-net0 -netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce \ + -device virtio-net-pci,mac=52:54:00:00:00:01,netdev=mynet1,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on \ + -vnc :12 -daemonize + + qemu-system-x86_64 -name us-vhost-vm2 \ + -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \ + -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-2.img \ + -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6005-:22 \ + -chardev socket,id=char1,path=./vhost-net1 -netdev type=vhost-user,id=mynet2,chardev=char1,vhostforce \ + -device virtio-net-pci,mac=52:54:00:00:00:02,netdev=mynet2,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on \ + -vnc :11 -daemonize + +3. On VM1, set virtio device IP and run arp protocal:: + + ifconfig ens3 1.1.1.2 + arp -s 1.1.1.8 52:54:00:00:00:02 + +4. On VM2, set virtio device IP and run arp protocal:: + + ifconfig ens3 1.1.1.8 + arp -s 1.1.1.2 52:54:00:00:00:01 + +5. Check the iperf performance between two VMs by below commands:: + + Under VM1, run: `iperf -s -i 1` + Under VM2, run: `iperf -c 1.1.1.2 -i 1 -t 30` + +6. Check both 2VMs can receive and send big packets to each other:: + + testpmd>show port xstats all + Port 0 should have tx packets above 1522 + Port 1 should have rx packets above 1522 + +7. Check iperf throughput can get expected data. + +Test Case 3: Perf VM2VM packed ring vhost-user/virtio-net test with tcp traffic +=============================================================================== + +1. Launch the Vhost sample by below commands:: + + rm -rf vhost-net* + ./testpmd -l 2-4 -n 4 --socket-mem 2048,2048 --legacy-mem --no-pci --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net0,queues=1' --vdev 'net_vhost1,iface=vhost-net1,queues=1' -- -i --nb-cores=2 --txd=1024 --rxd=1024 + testpmd>start + +2. Launch VM1 and VM2:: + + qemu-system-x86_64 -name us-vhost-vm1 \ + -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \ + -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-1.img \ + -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6004-:22 \ + -chardev socket,id=char0,path=./vhost-net0 -netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce \ + -device virtio-net-pci,mac=52:54:00:00:00:01,netdev=mynet1,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,packed=on \ + -vnc :12 -daemonize + + qemu-system-x86_64 -name us-vhost-vm2 \ + -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \ + -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-2.img \ + -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6005-:22 \ + -chardev socket,id=char1,path=./vhost-net1 -netdev type=vhost-user,id=mynet2,chardev=char1,vhostforce \ + -device virtio-net-pci,mac=52:54:00:00:00:02,netdev=mynet2,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,packed=on \ + -vnc :11 -daemonize + +3. On VM1, set virtio device IP and run arp protocal:: + + ifconfig ens3 1.1.1.2 + arp -s 1.1.1.8 52:54:00:00:00:02 + +4. On VM2, set virtio device IP and run arp protocal:: + + ifconfig ens3 1.1.1.8 + arp -s 1.1.1.2 52:54:00:00:00:01 + +5. Check the iperf performance between two VMs by below commands:: + + Under VM1, run: `iperf -s -i 1` + Under VM2, run: `iperf -c 1.1.1.2 -i 1 -t 30` + +6. Check both 2VMs can receive and send big packets to each other:: + + testpmd>show port xstats all + Port 0 should have tx packets above 1522 + Port 1 should have rx packets above 1522 + +7. Check iperf throughput can get expected data. + +Test Case 4: Perf VM2VM packed ring vhost-user/virtio-net dequeue zero-copy test with tcp traffic +================================================================================================= + +1. Launch the Vhost sample by below commands:: + + rm -rf vhost-net* + ./testpmd -l 2-4 -n 4 --socket-mem 2048,2048 --legacy-mem --no-pci --file-prefix=vhost --vdev 'net_vhost0,iface=vhost-net0,queues=1,dequeue-zero-copy=1' --vdev 'net_vhost1,iface=vhost-net1,queues=1,dequeue-zero-copy=1' -- -i --nb-cores=2 --txd=1024 --rxd=1024 + testpmd>start + +2. Launch VM1 and VM2:: + + qemu-system-x86_64 -name us-vhost-vm1 \ + -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \ + -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-1.img \ + -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6004-:22 \ + -chardev socket,id=char0,path=./vhost-net0 -netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce \ + -device virtio-net-pci,mac=52:54:00:00:00:01,netdev=mynet1,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,packed=on \ + -vnc :12 -daemonize + + qemu-system-x86_64 -name us-vhost-vm2 \ + -cpu host -enable-kvm -m 2048 -object memory-backend-file,id=mem,size=2048M,mem-path=/mnt/huge,share=on -numa node,memdev=mem -mem-prealloc \ + -smp cores=2,sockets=1 -drive file=/home/osimg/ubuntu16-2.img \ + -monitor unix:/tmp/vm2_monitor.sock,server,nowait -net nic,vlan=2,macaddr=00:00:00:08:e8:aa,addr=1f -net user,vlan=2,hostfwd=tcp:127.0.0.1:6005-:22 \ + -chardev socket,id=char1,path=./vhost-net1 -netdev type=vhost-user,id=mynet2,chardev=char1,vhostforce \ + -device virtio-net-pci,mac=52:54:00:00:00:02,netdev=mynet2,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on,packed=on \ + -vnc :11 -daemonize + +3. On VM1, set virtio device IP and run arp protocal:: + + ifconfig ens3 1.1.1.2 + arp -s 1.1.1.8 52:54:00:00:00:02 + +4. On VM2, set virtio device IP and run arp protocal:: + + ifconfig ens3 1.1.1.8 + arp -s 1.1.1.2 52:54:00:00:00:01 + +5. Check the iperf performance between two VMs by below commands:: + + Under VM1, run: `iperf -s -i 1` + Under VM2, run: `iperf -c 1.1.1.2 -i 1 -t 30` + +6. Check both 2VMs can receive and send big packets to each other:: + + testpmd>show port xstats all + Port 0 should have tx packets above 1522 + Port 1 should have rx packets above 1522 + +7. Check iperf throughput can get expected data. \ No newline at end of file -- 2.17.1