test suite reviews and discussions
 help / color / mirror / Atom feed
* [dts] [PATCH] test_plans: add VLAN ethertype config
@ 2016-05-17  6:16 Yulong Pei
  2016-05-23 20:48 ` Liu, Yong
  0 siblings, 1 reply; 2+ messages in thread
From: Yulong Pei @ 2016-05-17  6:16 UTC (permalink / raw)
  To: dts; +Cc: Yulong Pei

Signed-off-by: Yulong Pei <yulong.pei@intel.com>
---
 test_plans/vlan_ethertype_config_test_plan.rst | 231 +++++++++++++++++++++++++
 1 file changed, 231 insertions(+)
 create mode 100644 test_plans/vlan_ethertype_config_test_plan.rst

diff --git a/test_plans/vlan_ethertype_config_test_plan.rst b/test_plans/vlan_ethertype_config_test_plan.rst
new file mode 100644
index 0000000..27dbda7
--- /dev/null
+++ b/test_plans/vlan_ethertype_config_test_plan.rst
@@ -0,0 +1,231 @@
+.. Copyright (c) <2016>, Intel Corporation
+   All rights reserved.
+   
+   Redistribution and use in source and binary forms, with or without
+   modification, are permitted provided that the following conditions
+   are met:
+   
+   - Redistributions of source code must retain the above copyright
+     notice, this list of conditions and the following disclaimer.
+   
+   - Redistributions in binary form must reproduce the above copyright
+     notice, this list of conditions and the following disclaimer in
+     the documentation and/or other materials provided with the
+     distribution.
+   
+   - Neither the name of Intel Corporation nor the names of its
+     contributors may be used to endorse or promote products derived
+     from this software without specific prior written permission.
+   
+   THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
+   "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
+   LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
+   FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
+   COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
+   INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
+   (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
+   SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
+   HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
+   STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
+   ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED
+   OF THE POSSIBILITY OF SUCH DAMAGE.
+
+============================================
+Fortville, Support for VLAN ethertype config
+============================================
+
+Description
+===========
+for single vlan defaut TPID is 0x8100.
+for QinQ, default S-Tag+C-Tag VLAN TPIDs 0x88A8 + 0x8100. 
+This feature implemented configuration of VLAN ethertype TPID,
+such as changing single vlan TPID 0x8100 to 0xA100, or changing QinQ "0x88A8 + 0x8100" \
+to "0x9100+0xA100" or "0x8100+0x8100"
+
+Prerequisites
+=============
+
+1. Hardware:
+   one Fortville NIC (4x 10G or 2x10G or 2x40G or 1x10G) 
+  
+2. software: 
+  dpdk: http://dpdk.org/git/dpdk
+  scapy: http://www.secdev.org/projects/scapy/
+
+3. Assuming that DUT ports ``0`` and ``1`` are connected to the tester's port ``A`` and ``B``.
+
+Test Case 1: change VLAN TPID
+=================================
+1) start testpmd, start in rxonly mode,
+
+./testpmd -c 0xff -n 4 -- -i --portmask=0x3 --txqflags=0
+testpmd> set fwd rxonly
+testpmd> set verbose 1
+testpmd> start
+
+2) change VLAN TPIDs to 0xA100,
+
+testpmd> vlan set inner tpid 0xA100 0
+
+3) send a packet with VLAN TPIDs = 0xA100, verify it can be recognized as vlan packet.
+
+Test Case 2: test VLAN filtering on/off
+=======================================
+1) start testpmd, setup vlan filter on, start in mac forwarding mode
+
+./testpmd -c 0xff -n 4 -- -i --portmask=0x3 --txqflags=0
+testpmd> set fwd mac
+testpmd> vlan set filter on 0
+testpmd> start
+
+2) send 1 packet with the VLAN Tag 16 on port ``A``,
+Verify that the VLAN packet cannot be received in port ``B``.
+
+3) disable vlan filtering on port ``0``::
+
+testpmd> vlan set filter off 0
+
+4) send 1 packet with the VLAN Tag 16 on port ``A``,
+Verify that the VLAN packet can be received in port ``B``.
+
+Test Case 3: test adding VLAN Tag Identifier with changing VLAN TPID
+====================================================================
+
+1) start testpmd, setup vlan filter on, start in mac forwarding mode,
+
+./testpmd -c 0xff -n 4 -- -i --portmask=0x3 --txqflags=0
+testpmd> set fwd mac
+testpmd> vlan set filter on 0
+testpmd> vlan set strip off 0
+testpmd> start
+
+2) Add a VLAN Tag Identifier ``16`` on port ``0``::
+
+testpmd> rx_vlan add 16 0
+
+3) send 1 packet with the VLAN Tag 16 on port ``A``, 
+Verify that the VLAN packet can be received in port ``B`` and TPID is 0x8100
+
+4) Change VLAN TPID to 0xA100 on port ``0``
+
+testpmd> vlan set inner tpid 0xA100 0
+
+5) send 1 packet with VLAN TPID 0xA100 and VLAN Tag 16 on port ``A``, 
+Verify that the VLAN packet can be received in port ``B`` and TPID is 0xA100
+
+4) Remove the VLAN Tag Identifier ``16`` on port ``0``::
+
+testpmd> rx_vlan rm 16 0
+
+5) send 1 packet with VLAN TPID 0xA100 and VLAN Tag 16 on port ``A``, 
+Verify that the VLAN packet cannot be received in port ``B``.
+
+Test Case 4: test VLAN header striping with changing VLAN TPID
+==============================================================
+
+1) start testpmd, setup vlan filter off, vlan strip on, start in mac forwarding mode,
+
+./testpmd -c 0xff -n 4 -- -i --portmask=0x3 --txqflags=0
+testpmd> set fwd mac
+testpmd> vlan set filter off 0
+testpmd> vlan set strip on 0
+testpmd> start
+
+2) send 1 packet with the VLAN Tag 16 on port ``A``, 
+Verify that packet received in port ``B`` without VLAN Tag Identifier
+
+3) Change VLAN TPID to 0xA100 on port ``0``
+
+testpmd> vlan set inner tpid 0xA100 0
+
+4) send 1 packet with VLAN TPID 0xA100 and VLAN Tag 16 on port ``A``, 
+Verify that packet received in port ``B`` without VLAN Tag Identifier
+
+5) Disable vlan header striping on port ``0``::
+
+testpmd> vlan set strip off 0
+
+6) send 1 packet with VLAN TPID 0xA100 and VLAN Tag 16 on port ``A``, 
+Verify that packet received in port ``B`` with VLAN Tag Identifier.
+
+
+Test Case 5: test VLAN header inserting with changing VLAN TPID
+===============================================================
+
+1) start testpmd, enable vlan packet forwarding, start in mac forwarding mode,
+
+./testpmd -c 0xff -n 4 -- -i --portmask=0x3 --txqflags=0
+testpmd> set fwd mac
+testpmd> vlan set filter off 0
+testpmd> vlan set strip off 0
+testpmd> start
+
+2) Insert VLAN Tag Identifier ``16`` on port ``1``::
+
+testpmd> tx_vlan set 1 16
+
+3) send 1 packet without VLAN Tag Identifier on port ``A``,
+Verify that packet received in port ``B`` with VLAN Tag Identifier 16 and TPID is 0x8100
+
+4) Change VLAN TPID to 0xA100 on port ``1``
+
+testpmd> vlan set inner tpid 0xA100 1
+
+5)send 1 packet without VLAN Tag Identifier on port ``A``,
+Verify that packet received in port ``B`` with VLAN Tag Identifier 16 and TPID is 0xA100.
+
+6) Delete the VLAN Tag Identifier ``16`` on port ``1``::
+
+testpmd> tx_vlan reset 1
+
+7) send 1 packet without VLAN Tag Identifieron port ``A``,
+Verify that packet received in port ``B`` without VLAN Tag Identifier 16.
+
+
+Test Case 6: Change S-Tag and C-Tag within QinQ
+=================================================
+
+1) start testpmd, enable QinQ, start in rxonly mode,
+
+./testpmd -c 0xff -n 4 -- -i --portmask=0x3 --txqflags=0
+testpmd> vlan set qinq on 0
+testpmd> set fwd rxonly
+testpmd> set verbose 1
+testpmd> start
+
+2) change S-Tag+C-Tag VLAN TPIDs to 0x88A8 + 0x8100,
+
+testpmd> vlan set outer tpid 0x88A8 0
+testpmd> vlan set inner tpid 0x8100 0
+
+3) send a packet with set S-Tag+C-Tag VLAN TPIDs to 0x88A8 + 0x8100, 
+verify it can be recognized as qinq packet.
+
+4) change S-Tag+C-Tag VLAN TPIDs to 0x9100+0xA100,
+
+testpmd> vlan set outer tpid 0x9100 0
+testpmd> vlan set inner tpid 0xA100 0
+
+5) send a packet with set S-Tag+C-Tag VLAN TPIDs to 0x9100+0xA100, 
+verify it can be recognized as qinq packet.
+
+4) change S-Tag+C-Tag VLAN TPIDs to 0x8100+0x8100,
+
+testpmd> vlan set outer tpid 0x8100 0
+testpmd> vlan set inner tpid 0x8100 0
+
+5) send a packet with set S-Tag+C-Tag VLAN TPIDs to 0x8100+0x8100, 
+verify it can be recognized as qinq packet.
+
+
+Note:
+
+send packet with specific S-Tag+C-Tag VLAN TPID,
+1. wrpcap("qinq.pcap",[Ether(dst="68:05:CA:3A:2E:58")/Dot1Q(type=0x8100,vlan=16)/Dot1Q(type=0x8100,vlan=1006)/ IP(src="192.168.0.1", dst="192.168.0.2")]).
+2. hexedit qinq.pcap; change tpid field, "ctrl+w" to save, "ctrl+x" to exit.
+3. sendp(rdpcap("qinq.pcap"), iface="ens260f0").
+
+send packet with specific VLAN TPID,
+1. wrpcap("vlan.pcap",[Ether(dst="68:05:CA:3A:2E:58")/Dot1Q(type=0x8100,vlan=16)/IP(src="192.168.0.1", dst="192.168.0.2")]).
+2. hexedit vlan.pcap; change tpid field, "ctrl+w" to save, "ctrl+x" to exit.
+3. sendp(rdpcap("vlan.pcap"), iface="ens260f0").
-- 
2.1.0

^ permalink raw reply	[flat|nested] 2+ messages in thread

end of thread, other threads:[~2016-05-23 20:48 UTC | newest]

Thread overview: 2+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2016-05-17  6:16 [dts] [PATCH] test_plans: add VLAN ethertype config Yulong Pei
2016-05-23 20:48 ` Liu, Yong

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).