* [dts] [PATCH v1]test_plans: add softnic_test_plan.rst
@ 2019-05-27  3:31 Peng Yuan
  2019-05-27  4:04 ` Li, WenjieX A
  2019-05-29  2:59 ` Tu, Lijuan
  0 siblings, 2 replies; 3+ messages in thread
From: Peng Yuan @ 2019-05-27  3:31 UTC (permalink / raw)
  To: dts; +Cc: Peng Yuan

Add softnic_test_plan.rst to test_plans

Signed-off-by: Peng Yuan <yuan.peng@intel.com>

diff --git a/test_plans/softnic_test_plan.rst b/test_plans/softnic_test_plan.rst
new file mode 100644
index 0000000..9b75b1c
--- /dev/null
+++ b/test_plans/softnic_test_plan.rst
@@ -0,0 +1,137 @@
+.. Copyright (c) <2019>, Intel Corporation
+   All rights reserved.
+
+   Redistribution and use in source and binary forms, with or without
+   modification, are permitted provided that the following conditions
+   are met:
+
+   - Redistributions of source code must retain the above copyright
+     notice, this list of conditions and the following disclaimer.
+
+   - Redistributions in binary form must reproduce the above copyright
+     notice, this list of conditions and the following disclaimer in
+     the documentation and/or other materials provided with the
+     distribution.
+
+   - Neither the name of Intel Corporation nor the names of its
+     contributors may be used to endorse or promote products derived
+     from this software without specific prior written permission.
+
+   THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
+   "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
+   LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
+   FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
+   COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
+   INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
+   (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
+   SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
+   HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
+   STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
+   ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED
+   OF THE POSSIBILITY OF SUCH DAMAGE.
+
+===========
+softnic PMD
+===========
+
+Description
+===========
+The SoftNIC allows building custom NIC pipelines in SW. The Soft NIC pipeline
+is configurable through firmware (DPDK Packet Framework script).
+
+Prerequisites
+=============
+1. The DUT must have one 10G Ethernet port connected to a port on tester
+   that are controlled by the traffic generator::
+
+    dut_port_0 <---> tester_port_0
+
+   Assume the DUT 10G Ethernet port's pci device id is as the following::
+
+    dut_port_0 : "0000:05:00.0"
+
+   Bind it to dpdk igb_uio driver::
+
+    ./usertools/dpdk-devbind.py -b igb_uio 05:00.0
+
+2. Change ./drivers/net/softnic/firmware.cli to meet the specific test environment.
+
+3. Start softnic with following command line::
+
+    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
+    --vdev 'net_softnic0,firmware=./drivers/net/softnic/firmware.cli,cpu_id=1,conn_port=8086' \
+    -- -i --forward-mode=softnic --portmask=0x2
+    testpmd> start
+
+   Or Start softnic with default hierarchy Qos with following command line::
+
+    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
+    --vdev 'net_softnic0,firmware=./drivers/net/softnic/firmware.cli,cpu_id=1,conn_port=8086' \
+    -- -i --forward-mode=softnic --portmask=0x2
+    testpmd> set port tm hierarchy default 1
+    testpmd> start
+
+Test Case 1: softnic performance
+================================
+1. Start softnic::
+
+    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
+    --vdev 'net_softnic0,firmware=./drivers/net/softnic/firmware.cli,cpu_id=1,conn_port=8086' \
+    -- -i --forward-mode=softnic --portmask=0x2
+    testpmd> start
+
+2. Send packet at line rate from traffic generator (IXIA or other) with packet size from 64~1518B.
+3. Check performance number is same as the physical NIC's performance number, no performance drop.
+
+Test Case 2: shaping for pipe
+=============================
+1. The specifications of the default Hierarchical Scheduler are as follows:
+
+    Root node (x1, level 0)
+    Subport node (x1, level 1)
+    Pipe node (x4096, level 2)
+    Traffic Class node (x16348, level 3)
+    Queue node (x65536, level 4)
+
+2. Start softnic with the default hierarchy Qos::
+
+    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
+    --vdev 'net_softnic0,firmware=./drivers/net/softnic/tm_firmware.cli,cpu_id=1,conn_port=8086' \
+    -- -i --forward-mode=softnic --portmask=0x2
+    testpmd> set port tm hierarchy default 1
+    testpmd> start
+
+3. Send per flow traffic with 100% line rate, verify output flow rate is 1/4096 subport rate.
+
+Test Case 3: NAT
+================
+1. Set SNAT with proto tcp test, edit nat_firmware.cli to change "table action" as below::
+
+    table action profile AP0 ipv4 offset 270 fwd nat src proto tcp
+
+(a). Start softnic::
+
+    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
+    --vdev 'net_softnic0,firmware=./drivers/net/softnic/nat_firmware.cli,cpu_id=1,conn_port=8086' \
+    -- -i --forward-mode=softnic --portmask=0x2
+    testpmd> start
+
+(b). Sent packet, verify the received packet's ipaddr and port was changed as expected.
+
+2. Set DNAT with proto tcp test, edit nat_firmware.cli to change "table action" as below::
+
+    table action profile AP0 ipv4 offset 270 fwd nat dst proto tcp
+
+   Then re-run step (a) & step (b).
+
+3. Set SNAT with proto udp test, edit nat_firmware.cli to change "table action" as below::
+
+    table action profile AP0 ipv4 offset 270 fwd nat src proto udp
+
+   Then re-run step (a) & step (b).
+
+4. Set DNAT with proto udp test, edit nat_firmware.cli to change "table action" as below::
+
+    table action profile AP0 ipv4 offset 270 fwd nat dst proto udp
+
+   Then re-run step (a) & step (b).
-- 
2.14.3


^ permalink raw reply	[flat|nested] 3+ messages in thread

* Re: [dts] [PATCH v1]test_plans: add softnic_test_plan.rst
  2019-05-27  3:31 [dts] [PATCH v1]test_plans: add softnic_test_plan.rst Peng Yuan
@ 2019-05-27  4:04 ` Li, WenjieX A
  2019-05-29  2:59 ` Tu, Lijuan
  1 sibling, 0 replies; 3+ messages in thread
From: Li, WenjieX A @ 2019-05-27  4:04 UTC (permalink / raw)
  To: Peng, Yuan, dts; +Cc: Peng, Yuan

Reviewed-by: Wenjie <wenjiex.a.li@intel.com>

> -----Original Message-----
> From: dts [mailto:dts-bounces@dpdk.org] On Behalf Of Peng Yuan
> Sent: Monday, May 27, 2019 11:32 AM
> To: dts@dpdk.org
> Cc: Peng, Yuan <yuan.peng@intel.com>
> Subject: [dts] [PATCH v1]test_plans: add softnic_test_plan.rst
> 
> Add softnic_test_plan.rst to test_plans
> 
> Signed-off-by: Peng Yuan <yuan.peng@intel.com>
> 
> diff --git a/test_plans/softnic_test_plan.rst
> b/test_plans/softnic_test_plan.rst
> new file mode 100644
> index 0000000..9b75b1c
> --- /dev/null
> +++ b/test_plans/softnic_test_plan.rst
> @@ -0,0 +1,137 @@
> +.. Copyright (c) <2019>, Intel Corporation
> +   All rights reserved.
> +
> +   Redistribution and use in source and binary forms, with or without
> +   modification, are permitted provided that the following conditions
> +   are met:
> +
> +   - Redistributions of source code must retain the above copyright
> +     notice, this list of conditions and the following disclaimer.
> +
> +   - Redistributions in binary form must reproduce the above copyright
> +     notice, this list of conditions and the following disclaimer in
> +     the documentation and/or other materials provided with the
> +     distribution.
> +
> +   - Neither the name of Intel Corporation nor the names of its
> +     contributors may be used to endorse or promote products derived
> +     from this software without specific prior written permission.
> +
> +   THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
> CONTRIBUTORS
> +   "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT
> NOT
> +   LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
> FITNESS
> +   FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
> +   COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT,
> INDIRECT,
> +   INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
> +   (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE
> GOODS OR
> +   SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
> +   HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
> CONTRACT,
> +   STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
> +   ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
> ADVISED
> +   OF THE POSSIBILITY OF SUCH DAMAGE.
> +
> +===========
> +softnic PMD
> +===========
> +
> +Description
> +===========
> +The SoftNIC allows building custom NIC pipelines in SW. The Soft NIC
> +pipeline is configurable through firmware (DPDK Packet Framework script).
> +
> +Prerequisites
> +=============
> +1. The DUT must have one 10G Ethernet port connected to a port on
> tester
> +   that are controlled by the traffic generator::
> +
> +    dut_port_0 <---> tester_port_0
> +
> +   Assume the DUT 10G Ethernet port's pci device id is as the following::
> +
> +    dut_port_0 : "0000:05:00.0"
> +
> +   Bind it to dpdk igb_uio driver::
> +
> +    ./usertools/dpdk-devbind.py -b igb_uio 05:00.0
> +
> +2. Change ./drivers/net/softnic/firmware.cli to meet the specific test
> environment.
> +
> +3. Start softnic with following command line::
> +
> +    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
> +    --vdev
> 'net_softnic0,firmware=./drivers/net/softnic/firmware.cli,cpu_id=1,conn_p
> ort=8086' \
> +    -- -i --forward-mode=softnic --portmask=0x2
> +    testpmd> start
> +
> +   Or Start softnic with default hierarchy Qos with following command line::
> +
> +    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
> +    --vdev
> 'net_softnic0,firmware=./drivers/net/softnic/firmware.cli,cpu_id=1,conn_p
> ort=8086' \
> +    -- -i --forward-mode=softnic --portmask=0x2
> +    testpmd> set port tm hierarchy default 1
> +    testpmd> start
> +
> +Test Case 1: softnic performance
> +================================
> +1. Start softnic::
> +
> +    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
> +    --vdev
> 'net_softnic0,firmware=./drivers/net/softnic/firmware.cli,cpu_id=1,conn_p
> ort=8086' \
> +    -- -i --forward-mode=softnic --portmask=0x2
> +    testpmd> start
> +
> +2. Send packet at line rate from traffic generator (IXIA or other) with
> packet size from 64~1518B.
> +3. Check performance number is same as the physical NIC's performance
> number, no performance drop.
> +
> +Test Case 2: shaping for pipe
> +=============================
> +1. The specifications of the default Hierarchical Scheduler are as follows:
> +
> +    Root node (x1, level 0)
> +    Subport node (x1, level 1)
> +    Pipe node (x4096, level 2)
> +    Traffic Class node (x16348, level 3)
> +    Queue node (x65536, level 4)
> +
> +2. Start softnic with the default hierarchy Qos::
> +
> +    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
> +    --vdev
> 'net_softnic0,firmware=./drivers/net/softnic/tm_firmware.cli,cpu_id=1,con
> n_port=8086' \
> +    -- -i --forward-mode=softnic --portmask=0x2
> +    testpmd> set port tm hierarchy default 1
> +    testpmd> start
> +
> +3. Send per flow traffic with 100% line rate, verify output flow rate is
> 1/4096 subport rate.
> +
> +Test Case 3: NAT
> +================
> +1. Set SNAT with proto tcp test, edit nat_firmware.cli to change "table
> action" as below::
> +
> +    table action profile AP0 ipv4 offset 270 fwd nat src proto tcp
> +
> +(a). Start softnic::
> +
> +    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
> +    --vdev
> 'net_softnic0,firmware=./drivers/net/softnic/nat_firmware.cli,cpu_id=1,co
> nn_port=8086' \
> +    -- -i --forward-mode=softnic --portmask=0x2
> +    testpmd> start
> +
> +(b). Sent packet, verify the received packet's ipaddr and port was changed
> as expected.
> +
> +2. Set DNAT with proto tcp test, edit nat_firmware.cli to change "table
> action" as below::
> +
> +    table action profile AP0 ipv4 offset 270 fwd nat dst proto tcp
> +
> +   Then re-run step (a) & step (b).
> +
> +3. Set SNAT with proto udp test, edit nat_firmware.cli to change "table
> action" as below::
> +
> +    table action profile AP0 ipv4 offset 270 fwd nat src proto udp
> +
> +   Then re-run step (a) & step (b).
> +
> +4. Set DNAT with proto udp test, edit nat_firmware.cli to change "table
> action" as below::
> +
> +    table action profile AP0 ipv4 offset 270 fwd nat dst proto udp
> +
> +   Then re-run step (a) & step (b).
> --
> 2.14.3


^ permalink raw reply	[flat|nested] 3+ messages in thread

* Re: [dts] [PATCH v1]test_plans: add softnic_test_plan.rst
  2019-05-27  3:31 [dts] [PATCH v1]test_plans: add softnic_test_plan.rst Peng Yuan
  2019-05-27  4:04 ` Li, WenjieX A
@ 2019-05-29  2:59 ` Tu, Lijuan
  1 sibling, 0 replies; 3+ messages in thread
From: Tu, Lijuan @ 2019-05-29  2:59 UTC (permalink / raw)
  To: Peng, Yuan, dts; +Cc: Peng, Yuan

Applied, thanks

> -----Original Message-----
> From: dts [mailto:dts-bounces@dpdk.org] On Behalf Of Peng Yuan
> Sent: Monday, May 27, 2019 11:32 AM
> To: dts@dpdk.org
> Cc: Peng, Yuan <yuan.peng@intel.com>
> Subject: [dts] [PATCH v1]test_plans: add softnic_test_plan.rst
> 
> Add softnic_test_plan.rst to test_plans
> 
> Signed-off-by: Peng Yuan <yuan.peng@intel.com>
> 
> diff --git a/test_plans/softnic_test_plan.rst
> b/test_plans/softnic_test_plan.rst
> new file mode 100644
> index 0000000..9b75b1c
> --- /dev/null
> +++ b/test_plans/softnic_test_plan.rst
> @@ -0,0 +1,137 @@
> +.. Copyright (c) <2019>, Intel Corporation
> +   All rights reserved.
> +
> +   Redistribution and use in source and binary forms, with or without
> +   modification, are permitted provided that the following conditions
> +   are met:
> +
> +   - Redistributions of source code must retain the above copyright
> +     notice, this list of conditions and the following disclaimer.
> +
> +   - Redistributions in binary form must reproduce the above copyright
> +     notice, this list of conditions and the following disclaimer in
> +     the documentation and/or other materials provided with the
> +     distribution.
> +
> +   - Neither the name of Intel Corporation nor the names of its
> +     contributors may be used to endorse or promote products derived
> +     from this software without specific prior written permission.
> +
> +   THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
> CONTRIBUTORS
> +   "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
> +   LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
> FITNESS
> +   FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
> +   COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT,
> INDIRECT,
> +   INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
> +   (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
> OR
> +   SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
> +   HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
> CONTRACT,
> +   STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
> +   ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
> ADVISED
> +   OF THE POSSIBILITY OF SUCH DAMAGE.
> +
> +===========
> +softnic PMD
> +===========
> +
> +Description
> +===========
> +The SoftNIC allows building custom NIC pipelines in SW. The Soft NIC
> +pipeline is configurable through firmware (DPDK Packet Framework script).
> +
> +Prerequisites
> +=============
> +1. The DUT must have one 10G Ethernet port connected to a port on tester
> +   that are controlled by the traffic generator::
> +
> +    dut_port_0 <---> tester_port_0
> +
> +   Assume the DUT 10G Ethernet port's pci device id is as the following::
> +
> +    dut_port_0 : "0000:05:00.0"
> +
> +   Bind it to dpdk igb_uio driver::
> +
> +    ./usertools/dpdk-devbind.py -b igb_uio 05:00.0
> +
> +2. Change ./drivers/net/softnic/firmware.cli to meet the specific test
> environment.
> +
> +3. Start softnic with following command line::
> +
> +    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
> +    --vdev
> 'net_softnic0,firmware=./drivers/net/softnic/firmware.cli,cpu_id=1,conn_por
> t=8086' \
> +    -- -i --forward-mode=softnic --portmask=0x2
> +    testpmd> start
> +
> +   Or Start softnic with default hierarchy Qos with following command line::
> +
> +    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
> +    --vdev
> 'net_softnic0,firmware=./drivers/net/softnic/firmware.cli,cpu_id=1,conn_por
> t=8086' \
> +    -- -i --forward-mode=softnic --portmask=0x2
> +    testpmd> set port tm hierarchy default 1
> +    testpmd> start
> +
> +Test Case 1: softnic performance
> +================================
> +1. Start softnic::
> +
> +    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
> +    --vdev
> 'net_softnic0,firmware=./drivers/net/softnic/firmware.cli,cpu_id=1,conn_por
> t=8086' \
> +    -- -i --forward-mode=softnic --portmask=0x2
> +    testpmd> start
> +
> +2. Send packet at line rate from traffic generator (IXIA or other) with packet
> size from 64~1518B.
> +3. Check performance number is same as the physical NIC's performance
> number, no performance drop.
> +
> +Test Case 2: shaping for pipe
> +=============================
> +1. The specifications of the default Hierarchical Scheduler are as follows:
> +
> +    Root node (x1, level 0)
> +    Subport node (x1, level 1)
> +    Pipe node (x4096, level 2)
> +    Traffic Class node (x16348, level 3)
> +    Queue node (x65536, level 4)
> +
> +2. Start softnic with the default hierarchy Qos::
> +
> +    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
> +    --vdev
> 'net_softnic0,firmware=./drivers/net/softnic/tm_firmware.cli,cpu_id=1,conn_
> port=8086' \
> +    -- -i --forward-mode=softnic --portmask=0x2
> +    testpmd> set port tm hierarchy default 1
> +    testpmd> start
> +
> +3. Send per flow traffic with 100% line rate, verify output flow rate is 1/4096
> subport rate.
> +
> +Test Case 3: NAT
> +================
> +1. Set SNAT with proto tcp test, edit nat_firmware.cli to change "table
> action" as below::
> +
> +    table action profile AP0 ipv4 offset 270 fwd nat src proto tcp
> +
> +(a). Start softnic::
> +
> +    ./x86_64-native-linuxapp-gcc/app/testpmd -l 23-25 -n 4 \
> +    --vdev
> 'net_softnic0,firmware=./drivers/net/softnic/nat_firmware.cli,cpu_id=1,conn
> _port=8086' \
> +    -- -i --forward-mode=softnic --portmask=0x2
> +    testpmd> start
> +
> +(b). Sent packet, verify the received packet's ipaddr and port was changed
> as expected.
> +
> +2. Set DNAT with proto tcp test, edit nat_firmware.cli to change "table
> action" as below::
> +
> +    table action profile AP0 ipv4 offset 270 fwd nat dst proto tcp
> +
> +   Then re-run step (a) & step (b).
> +
> +3. Set SNAT with proto udp test, edit nat_firmware.cli to change "table
> action" as below::
> +
> +    table action profile AP0 ipv4 offset 270 fwd nat src proto udp
> +
> +   Then re-run step (a) & step (b).
> +
> +4. Set DNAT with proto udp test, edit nat_firmware.cli to change "table
> action" as below::
> +
> +    table action profile AP0 ipv4 offset 270 fwd nat dst proto udp
> +
> +   Then re-run step (a) & step (b).
> --
> 2.14.3


^ permalink raw reply	[flat|nested] 3+ messages in thread

end of thread, other threads:[~2019-05-29  2:59 UTC | newest]

Thread overview: 3+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2019-05-27  3:31 [dts] [PATCH v1]test_plans: add softnic_test_plan.rst Peng Yuan
2019-05-27  4:04 ` Li, WenjieX A
2019-05-29  2:59 ` Tu, Lijuan

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).