* [dpdk-dev] pktgen counters not
@ 2016-06-20 14:16 Posadas, Emerson
0 siblings, 0 replies; 2+ messages in thread
From: Posadas, Emerson @ 2016-06-20 14:16 UTC (permalink / raw)
To: dev
Hello
I'm running the pktgen application to do some benchmarking. My current issue with pktgen is that I don't get any packet counted against the packet size on the application even after sending some traffic.
Flags:Port : P--------------:0 P--------------:1
Link State : <UP-10000-FD> <UP-10000-FD> ----TotalRate----
Pkts/s Max/Rx : 0/0 0/0 0/0
Max/Tx : 14194206/0 14194254/0 28388460/0
MBits/s Rx/Tx : 0/0 0/0 0/0
Broadcast : 0 0
Multicast : 0 0
64 Bytes : 0 0
65-127 : 0 0
128-255 : 0 0
256-511 : 0 0
512-1023 : 0 0
1024-1518 : 0 0
I'm using DPDK 16.04 with pktgen 3.0.00 and using the following pktgen configuration flags:
./app/app/x86_64-native-linuxapp-gcc/app/pktgen -c 0x1ff -n 2 -- -P -m "[1-4].0, [5-8].1"
My NIC device is a dual port 10GbE Intel Corporation 82599EB PCIe card.
EP
^ permalink raw reply [flat|nested] 2+ messages in thread
* Re: [dpdk-dev] pktgen counters not
@ 2016-06-20 17:23 Wiles, Keith
0 siblings, 0 replies; 2+ messages in thread
From: Wiles, Keith @ 2016-06-20 17:23 UTC (permalink / raw)
To: Posadas, Emerson, dev
Most of the counters come from the NIC hardware, but I have to do the different sizes in software. If the packet was received then it will get counted as that works in my machine and many others. Unless I broke something in Pktgen it would mean to me that the packets are not getting received by the hardware or something else is going on.
Regards,
Keith
On 6/20/16, 4:16 PM, "dev on behalf of Posadas, Emerson" <dev-bounces@dpdk.org on behalf of emerson.posadas@intel.com> wrote:
>Hello
>
>I'm running the pktgen application to do some benchmarking. My current issue with pktgen is that I don't get any packet counted against the packet size on the application even after sending some traffic.
>
> Flags:Port : P--------------:0 P--------------:1
>Link State : <UP-10000-FD> <UP-10000-FD> ----TotalRate----
>Pkts/s Max/Rx : 0/0 0/0 0/0
> Max/Tx : 14194206/0 14194254/0 28388460/0
>MBits/s Rx/Tx : 0/0 0/0 0/0
>Broadcast : 0 0
>Multicast : 0 0
> 64 Bytes : 0 0
> 65-127 : 0 0
> 128-255 : 0 0
> 256-511 : 0 0
> 512-1023 : 0 0
> 1024-1518 : 0 0
>
>I'm using DPDK 16.04 with pktgen 3.0.00 and using the following pktgen configuration flags:
>./app/app/x86_64-native-linuxapp-gcc/app/pktgen -c 0x1ff -n 2 -- -P -m "[1-4].0, [5-8].1"
>
>My NIC device is a dual port 10GbE Intel Corporation 82599EB PCIe card.
>
>EP
>
>
^ permalink raw reply [flat|nested] 2+ messages in thread
end of thread, other threads:[~2016-06-20 17:23 UTC | newest]
Thread overview: 2+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2016-06-20 14:16 [dpdk-dev] pktgen counters not Posadas, Emerson
2016-06-20 17:23 Wiles, Keith
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).