* [dpdk-users] Possible to rate limit a VF on ConnectX-3 ?
@ 2015-12-03  8:51 Jesper Wramberg
  2015-12-04 14:46 ` Jesper Wramberg
  0 siblings, 1 reply; 3+ messages in thread
From: Jesper Wramberg @ 2015-12-03  8:51 UTC (permalink / raw)
  To: users

Morning all,

I was wondering if anyone know if/how you can rate limit a virtual function
on a ConnectX-3 ?
I am running OFED 3.1 and NIC FW 2.34.5060 (latest from dell). I have tried
the following with no luck:

ip link set <pf> vf <x> rate <y>
mlnx_qos
mlnx_qcn

The closest I have gotten was with mlnx_qos but it seems I can only rate
limit all traffic or no traffic (using traffic class 0). I tried
manipulating the TCs with tc_wrap but it seem that all traffic falls into
user priority 0 or something ? I also tried using different TX queues in
DPDK but the result was the same. The other commands seems to have no
effect at all. My mlx4_core.conf file looks like this:

options mlx4_core port_type_array=2,2 num_vfs=3 probe_vf=3
log_num_mgm_entry_size=-1 fast_drop=1 use_prio=1 enable_qos=1
enable_vfs_qos=1

I simply tried to enable everything that might be relevant :-)
Alternatively, I also configured the transmitter using the VF to use one
specific VLAN with one specific priority. Unfortunately I couldn't seem to
rate limit based on VLAN or VLAN prio either :-(

Best Regards,
Jesper

^ permalink raw reply	[flat|nested] 3+ messages in thread

* Re: [dpdk-users] Possible to rate limit a VF on ConnectX-3 ?
  2015-12-03  8:51 [dpdk-users] Possible to rate limit a VF on ConnectX-3 ? Jesper Wramberg
@ 2015-12-04 14:46 ` Jesper Wramberg
  2015-12-04 21:07   ` Gilad Berman
  0 siblings, 1 reply; 3+ messages in thread
From: Jesper Wramberg @ 2015-12-04 14:46 UTC (permalink / raw)
  To: users

Hey all,

Just some info in case someone runs into a similar problem in the future.
It seems that you can use:
ip link set <pf> vf <x> vlan <y> qos <z>
to apply a QoS prio to a VF which translates directly to a user prio (which
can then be moved between traffic classes with different rate limits).
I can't seem to get this running with VGT, however, only with VST or
specific VLAN ids. So I guess my problem is partially solved :-) Ideally, I
would like to use VGT so the VF can transmit with any VLAN without any
changes to the packet. Unfortunately, I can't seem to figure out if/how
this works.

Best Regards,
Jesper

2015-12-03 9:51 GMT+01:00 Jesper Wramberg <jesper.wramberg@gmail.com>:

> Morning all,
>
> I was wondering if anyone know if/how you can rate limit a virtual
> function on a ConnectX-3 ?
> I am running OFED 3.1 and NIC FW 2.34.5060 (latest from dell). I have
> tried the following with no luck:
>
> ip link set <pf> vf <x> rate <y>
> mlnx_qos
> mlnx_qcn
>
> The closest I have gotten was with mlnx_qos but it seems I can only rate
> limit all traffic or no traffic (using traffic class 0). I tried
> manipulating the TCs with tc_wrap but it seem that all traffic falls into
> user priority 0 or something ? I also tried using different TX queues in
> DPDK but the result was the same. The other commands seems to have no
> effect at all. My mlx4_core.conf file looks like this:
>
> options mlx4_core port_type_array=2,2 num_vfs=3 probe_vf=3
> log_num_mgm_entry_size=-1 fast_drop=1 use_prio=1 enable_qos=1
> enable_vfs_qos=1
>
> I simply tried to enable everything that might be relevant :-)
> Alternatively, I also configured the transmitter using the VF to use one
> specific VLAN with one specific priority. Unfortunately I couldn't seem to
> rate limit based on VLAN or VLAN prio either :-(
>
> Best Regards,
> Jesper
>

^ permalink raw reply	[flat|nested] 3+ messages in thread

* Re: [dpdk-users] Possible to rate limit a VF on ConnectX-3 ?
  2015-12-04 14:46 ` Jesper Wramberg
@ 2015-12-04 21:07   ` Gilad Berman
  0 siblings, 0 replies; 3+ messages in thread
From: Gilad Berman @ 2015-12-04 21:07 UTC (permalink / raw)
  To: Jesper Wramberg, users

Jesper, 

QoS for VF currently working only for VST mode (see the user's guide). Let's take it offline (i.e mail me in private) to avoid spamming the list (and them we can post solution here) and we'll try to sort this out. 


Gilad Berman | Staff System Engineer | Business Development | Mellanox Technologies Ltd. 
Work: +972 52 2554262| 6 Ha’Barzel St. Tel Aviv 6971010, Israel


-----Original Message-----
From: users [mailto:users-bounces@dpdk.org] On Behalf Of Jesper Wramberg
Sent: Friday, December 04, 2015 4:46 PM
To: users@dpdk.org
Subject: Re: [dpdk-users] Possible to rate limit a VF on ConnectX-3 ?

Hey all,

Just some info in case someone runs into a similar problem in the future.
It seems that you can use:
ip link set <pf> vf <x> vlan <y> qos <z> to apply a QoS prio to a VF which translates directly to a user prio (which can then be moved between traffic classes with different rate limits).
I can't seem to get this running with VGT, however, only with VST or specific VLAN ids. So I guess my problem is partially solved :-) Ideally, I would like to use VGT so the VF can transmit with any VLAN without any changes to the packet. Unfortunately, I can't seem to figure out if/how this works.

Best Regards,
Jesper

2015-12-03 9:51 GMT+01:00 Jesper Wramberg <jesper.wramberg@gmail.com>:

> Morning all,
>
> I was wondering if anyone know if/how you can rate limit a virtual 
> function on a ConnectX-3 ?
> I am running OFED 3.1 and NIC FW 2.34.5060 (latest from dell). I have 
> tried the following with no luck:
>
> ip link set <pf> vf <x> rate <y>
> mlnx_qos
> mlnx_qcn
>
> The closest I have gotten was with mlnx_qos but it seems I can only 
> rate limit all traffic or no traffic (using traffic class 0). I tried 
> manipulating the TCs with tc_wrap but it seem that all traffic falls 
> into user priority 0 or something ? I also tried using different TX 
> queues in DPDK but the result was the same. The other commands seems 
> to have no effect at all. My mlx4_core.conf file looks like this:
>
> options mlx4_core port_type_array=2,2 num_vfs=3 probe_vf=3
> log_num_mgm_entry_size=-1 fast_drop=1 use_prio=1 enable_qos=1
> enable_vfs_qos=1
>
> I simply tried to enable everything that might be relevant :-) 
> Alternatively, I also configured the transmitter using the VF to use 
> one specific VLAN with one specific priority. Unfortunately I couldn't 
> seem to rate limit based on VLAN or VLAN prio either :-(
>
> Best Regards,
> Jesper
>

^ permalink raw reply	[flat|nested] 3+ messages in thread

end of thread, other threads:[~2015-12-04 21:07 UTC | newest]

Thread overview: 3+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2015-12-03  8:51 [dpdk-users] Possible to rate limit a VF on ConnectX-3 ? Jesper Wramberg
2015-12-04 14:46 ` Jesper Wramberg
2015-12-04 21:07   ` Gilad Berman

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).